| Applicable Models: |
No Loading (Check of Electrical Systems) |
|
| |
| Check Method of Causes | Repair Method | Explanation Figures |
[2]Checking the Electrical Systems |
| Power Supply Board | |
|
|
|
1. Connect the AC adapter, and turn on the power of the main unit.
2. Obtain the manual training program, set the pedal torque setting to 4.0kg·m, and rotate the pedal at the rate of 50 rpm. If you can rotate it quite easily, no load will be applied.
3. Replace the control unit with a brand new one.
4. Again, check the torque status under the manual training |
|
| |
program. |
|
| |
t When the pedal torque is loaded, the control unit is | Replace the control unit with a brand new one. |
| |
defective. |
| ||
|
| ||
When no torque loading is possible, proceed to the following | Fig. 1 | Fig. 2 | |
procedures. | |||
Normal when zero (0) |
| ||
1. Turn off the power, and loosen the four screws on the |
| ||
|
| ||
handlebar stem to remove the control unit. (Fig. 1) |
|
|
2. Remove the cable connector which is connected to the back of the control unit. (Fig. 1)
3. Remove the frame cover. (See the Sections D1 & D2 "Removing the Frame Covers.")
4. Remove the
5. Using a tester, check for any |
|
|
| |
1s and Terminal 4s at both ends of the 5P cable which |
|
|
| |
connects the power supply board and the control unit. (Fig. 3) |
| Connector | ||
t When there is no shortcircuit, the 5P cable is disconnected. |
| |||
Replace the 5P cable with a brand new one. (See the | Terminal 4 | |||
| ||||
| Fig. 4 | |||
When it is | Section |
| ||
| 5P Cable |
| ||
1. Remove the connector |
| Connector Terminal 4 | ||
|
| |||
and measure the resistance across Terminals 2 and 3 of the |
| Fig. 3 |
| |
connector. When the reading is in the range of 9Ω and 14Ω, |
|
|
| |
the connector is all right. (Figs. 4 & 5) |
| Normal for 14V thru 19V |
| |
t When the meter reading is exceedingly large, the solenoid |
|
| ||
Replace the workload unit. (See the Sections |
|
| ||
coil is defective. |
|
| ||
t When the meter reading is in the acceptable range, the | Replace the power supply board. (See the Section |
|
| |
power supply board may be defective. |
|
| ||
|
|
| Connector | |
|
|
| Terminal 2 | |
|
|
| To Solenoid Coil | |
|
| Connector Terminal 3 |
| |
|
|
| ||
|
| Fig. 5 |
|
Cateye Ergociser Series 1000 Service Manual
T-5 No Loading (Check of Electrical Systems)