Applicable Models: EC-1200
MS-1 Replacing the Workload Unit (w/o Flywheel) (1)
àRemoving the Workload Unit
1.Remove the frame cover, by referring to the Sections
2.Detach the
3.Using a nipper or the like, cut the cable holder which fixes the
4.Remove the gear crank, by referring to the Section
5.Using a wrench, loosen the nuts, which fix the workload unit reinforcing metal base, on both the workload unit side and the frame side, and remove the metal base. (Fig. 3)
6.Remove the hexagon head bolts which fix the workload unit (two bolts on either right and left sides). Lift the entire workload unit upward until it comes off the workload unit fixing metal base, and remove the unit by shifting it either in the right or left side (Fig. 4). Be careful that the copper disk plate does not touch the frame.
| Workload Unit |
| Power Supply Board |
Cable Holder
Fig. 2
Power Supply
Board
Fig. 1
Wrench
Workload Unit
Reinforcing Metal Base
Fig. 3
the Workload Unit (w/o Flywheel) (1)
Workload Unit
Workload Unit Fixing Hexagon Head Bolt
Fig. 4
Cateye Ergociser Series 1000 Service Manual
MS-1 Replacing
35