Whirlpool W10150627A, W10150626A VentingRequirements, Burner Input Requirements, Dryer Gas Pipe

Page 8

Burner Input Requirements:

Elevations above 10,000 ft (3,048 m):

When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation.

Gas Supply Pressure Testing

The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than ½ psi.

Dryer Gas Pipe

The gas pipe that comes out through the rear of your dryer has a ³⁄₈" male pipe thread.

2"

(5.1 cm)

A

³⁄₄"

 

(1.9 cm)

A. ³⁄₈" NPT dryer pipe

VentingRequirements

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a concealed space of a building.

If using an existing vent system

Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.

Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.

Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance.

If this is a new vent system

Vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.

4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended.

4"

10.2 cm

4" (10.2 cm) heavy metal exhaust vent

DURASAFE™ vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the “Assistance or Service” section.

Rigid metal vent

For best drying performance, rigid metal vents are recommended.

Rigid metal vent is recommended to avoid crushing and kinking.

Flexible metal vent

Flexible metal vents are acceptable only if accessible for cleaning.

Flexible metal vent must be fully extended and supported when the dryer is in its final location.

Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.

Do not install flexible metal vent in enclosed walls, ceilings or floors.

Elbows

45° elbows provide better airflow than 90° elbows.

GoodBetter

Clamps

Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct. Do not use duct tape.

Clamp

8

Image 8
Contents Cabrio Fabric Care System GAS Dryer W10150626ATable DES Matières Dryer Safety Your safety and the safety of others are very importantImportant Safety Instructions LocationRequirements Installation InstructionsToolsandParts Mobile home installations require Mobile home Additional installation requirementsDryer Dimensions Electrical RequirementsGasSupplyRequirements Gas TypeGas Supply Line Gas supply connection requirementsIf using an existing vent system VentingRequirementsBurner Input Requirements Dryer Gas PipeExhaust Special provisions for mobile home installationsPlanVentSystem Install VentSystem Install LevelingLegsVent system chart Determine vent pathLevelDryer MakeGasConnectionConnectVent Remove the door assembly Reinstall the doorReverseDoorSwing Reverse the strikeCompleteInstallation If the dryer will not start, check the followingDryer USE StartingYourDryerTo use an Automatic Cycle To make changes during an Automatic CycleStatusLights Stopping,PausingorRestartingDryingandCycleTips Cycles Modifiers Options DryingRackOption EndofCycleSignalChangingCycles,Modifiers andOptions CleaningtheDryer Location CleaningtheLintScreenCleaningtheDryerInterior Dryer CareTroubleshooting VacationandMovingCareChangingtheDrumLight DryerOperationDryerResults InCanada AccessoriesIntheU.S.A Whirlpool Corporation Major Appliance Warranty CallSécurité DE LA Sécheuse Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Outillageetpièces Instructions D’INSTALLATIONExigences d’emplacement Spécifications électriques Dimensions de la sécheuseLinstallation dans une maison mobile exige Alimentationengaz Type de gazCanalisation d’arrivée de gaz Exigences concernant le raccordement au gazEn cas dutilisation du système dévacuation existant ExigencesconcernantlévacuationCanalisation d’arrivée de gaz de la sécheuse Planificationdusystèmed’évacuation ÉvacuationDéterminer litinéraire dacheminement du conduit Tableau des systèmes dévacuationInstallationdusystèmed’évacuation InstallationdespiedsdenivellementRaccordementaugaz Pour utilisation dans une maison mobileRaccordementduconduitd’évacuation RéglagedelaplombdelasécheuseInversiondusens douverturedela porte Dépose de la porteRéinstallation de la porte Inversion de la gâcheAcheverl’installation Si la sécheuse ne démarre pas, vérifier ce qui suitUtilisation dun programme automatique Utilisation DE LA SécheuseMiseenmarchedelasécheuse Arrêt,pauseouremiseenmarche Conseils pourleséchageetles programmesTémoins lumineux ProgrammesModificateurs Signaldefindeprogramme Optiondegrilledeséchage Changement des programmes après avoir appuyé sur StartModification des préréglages de niveau de séchage Utilisation de la grille de séchageNettoyagedelemplacementdelasécheuse Entretien DE LA SécheuseNettoyagedufiltreàcharpie Nettoyage avant chaque chargeNettoyagedel’intérieurdelasécheuse RetraitdelacharpieaccumuléeDéménagement Changementdel’ampouled’éclairagedutambourRésultatsdelasécheuse DépannageFonctionnementdelasécheuse Temps de programme trop court Charpie sur la chargeTaches sur la charge ou sur le tambour Charges avec faux plisPour plus d’assistance AccessoiresSi vous avez besoin de pièces de rechange Garantie DES Gros Appareils Ménagers Whirlpool Corporation Garantie Limitée DE UN ANW10150626A SP PN W10150627A Whirlpool Corporation All rights reserved