VENTING

Venting Requirements

Exhaust hoods:

Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow).

Recommended Styles:

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.

4"

(102 mm)

4" (102 mm) heavy metal exhaust vent

Only a 4" (102 mm) heavy metal exhaust vent and clamps may be used.

Do not use plastic or metal foil vent.

Rigid metal vent:

Recommended for best drying performance and to avoid crushing and kinking.

Flexible metal vent: (Acceptable only if accessible to clean) Must be fully extended and supported in final dryer location.

Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance.

Do not install in enclosed walls, ceilings, or floors. The total length should not exceed 73/4 ft. (2.4 m).

NOTE: If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review “Vent System Chart” and, if necessary, modify existing vent system to achieve best drying performance.

Louvered hood

Box hood

Acceptable Style:

Angled hood

Elbows:

45° elbows provide better airflow than 90° elbows.

Good Better

Clamps:

Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.

See “Venting Kits” for more information.

10

Image 10
Contents Table of Contents Table des matières Gaz É.-U. et Canada et Électrique Canada uniquementDryer Safety Page Tools needed for gas installations Tools needed for all installationsTools and Parts Parts needed Location RequirementsParts supplied You will needInstallation Spacing Installation clearancesWide Models Dryer Dimensions Installation spacing for recessed area or closetPrepare dryer for leveling legs Install Leveling LegsElectrical Requirements It is your responsibilityGas Supply Requirements Screw in leveling legsDryer gas pipe Burner input requirementsVenting Requirements Alternate installations for close clearances Recommended exhaust installationsOptional exhaust installations Plan Vent SystemVent System Chart Wide Long Vent Models Only Install Vent SystemVent System Chart Install exhaust hoodMake Gas Connection Connect VentLevel Dryer Complete Installation ChecklistTighten and adjust leveling legs Reverse Door Swing OptionalLift door off top screws Place towel on dryerRemove bottom screws Remove and transfer hinge hole plugsRotate outer door Remove screws from hingesRemove screws from door Super Wide Side-Swing DoorFlip door over Remove door strike Attach door hingesRemove door strike plug Remove bottom screws Wide Model Side-Swing DoorFlip door over Remove screws from door Attach door hingesRemove and transfer plugs Wide Model Side-Swing Door with Glass Flip door over Rotate outer door Separate inner from outer doorTroubleshooting Remove door strike Remove door strike plugSécurité de la sécheuse Page Outils nécessaires pour toutes les installations Outillage et piècesPièces fournies Exigences d’emplacementOutils nécessaires aux installations au gaz Pièces nécessairesEspacement pour une installation dans un Espacements d’installationEspacement pour une installation Encastrement ou dans un placardSpécifications électriques ’est à l’utilisateur qu’incombe la responsabilité dePréparer la sécheuse pour les pieds de nivellement Installation des pieds de nivellementSpécifications de l’alimentation en gaz Visser dans les pieds de nivellementCanalisation d’arrivée de gaz de la sécheuse Canalisation de gazExigences concernant le raccordement au gaz Caractéristiques d’alimentation du brûleurAltitudes supérieures à 10 000 pieds 3 048 m Épreuve sous pression de l’alimentation en gazExigences concernant l’evacuation Installations alternées pour dégagements étroits Installations d’évacuation recommandéesInstallations d’évacuation facultatives Planification du système d’évacuationDispositions spéciales pour les maisons mobiles Tableau des systèmes d’évacuationDéterminer l’itinéraire d’acheminement du conduit Installation du circuit d’évacuation Raccordement au gazRaccorder le conduit d’évacuation Déplacer la sécheuse à son emplacement finalRégler l’aplomb de la sécheuse La bouche d’évacuationInversion du sens de l’ouverture De la porte facultatif Achever l’installation liste de VérificationSi la sécheuse ne démarre pas, vérifier ce qui suit Soulever la porte pour la dégager des vis supérieures Ôter les vis inférieuresModèle large avec porte à grande ouverture latérale de Placer une serviette sur la sécheuse Contrôler l’alignement de la gâche de la portePorte à très grande ouverture latérale de Faire pivoter la porte externe Ôter les vis des charnièresÔter les vis du panneau de porte Retourner la porteRetirer la gâche de porte Retirer le bouchon d’obturation de la gâche de porte Modèle large avec porte à ouverture latérale deÔter les vis des charnières Retourner la porte Fixer les charnières de porte’aide des mêmes 4 vis Placer une serviette sur la sécheuse Faire pivoter la porte externe Dépannage W10115228B W10115229B-SP