Special provisions for mobile home installations:

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

The “Vent System Chart” provides venting requirements that will help achieve best drying performance.

Vent System Chart

 

Number of

Type

Box/louvered

Angled

 

 

90° turns or

of vent

hoods

hoods

 

 

elbows

 

 

 

 

 

0

Rigid metal

64 ft. (20 m)

58 ft. (17.7 m)

 

 

 

 

 

 

 

 

1

Rigid metal

54 ft. (16.5 m)

48 ft. (14.6 m)

 

 

 

 

 

 

 

 

2

Rigid metal

44 ft. (13.4 m)

38 ft. (11.6 m)

 

 

 

 

 

 

 

 

3

Rigid metal

35 ft. (10.7 m)

29 ft. (8.8 m)

 

 

 

 

 

 

 

 

4

Rigid metal

27 ft. (8.2 m)

21 ft. (6.4 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

Determine vent path:

Select route that will provide straightest and most direct path outdoors.

Plan installation to use fewest number of elbows and turns.

When using elbows or making turns, allow as much room as possible.

Bend vent gradually to avoid kinking. Use as few 90° turns as possible.

Determine vent length and elbows needed for best drying performance:

Use following “Vent System Chart” to determine type of vent material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified

in “Vent System Chart.” Exhaust systems longer than those specified will:

Shorten life of dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

NOTE: Side and bottom exhaust installations for 27" wide models have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.

Vent System Chart

(29" Wide Long Vent Models Only)

 

Number of

Type

Box/louvered, or

 

 

 

90° turns

of vent

Angled hoods

 

 

 

or elbows

 

 

 

 

 

 

 

 

 

 

 

0

Rigid metal

120 ft. (36.6 m)

 

 

 

 

 

 

 

 

 

1

Rigid metal

110 ft. (33.5 m)

 

 

 

 

 

 

 

 

 

2

Rigid metal

100 ft. (30.5 m)

 

 

 

 

 

 

 

 

 

3

Rigid metal

90 ft. (27.4 m)

 

 

 

 

 

 

 

 

 

4

Rigid metal

80 ft. (24.4 m)

 

 

 

 

 

 

 

 

 

5

Rigid metal

70 ft. (21.3 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install Vent System

1. Install exhaust hood

12" min.

(305 mm)

12" min. (305 mm)

Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood.

12

Image 12
Contents Table of Contents Table des matières Gaz É.-U. et Canada et Électrique Canada uniquementDryer Safety Page Tools needed for all installations Tools needed for gas installationsTools and Parts Location Requirements Parts suppliedParts needed You will needInstallation clearances Wide Models Dryer DimensionsInstallation Spacing Installation spacing for recessed area or closetInstall Leveling Legs Electrical RequirementsPrepare dryer for leveling legs It is your responsibilityGas Supply Requirements Screw in leveling legsDryer gas pipe Burner input requirementsVenting Requirements Recommended exhaust installations Optional exhaust installationsAlternate installations for close clearances Plan Vent SystemInstall Vent System Vent System ChartVent System Chart Wide Long Vent Models Only Install exhaust hoodMake Gas Connection Connect VentComplete Installation Checklist Tighten and adjust leveling legsLevel Dryer Reverse Door Swing OptionalPlace towel on dryer Remove bottom screwsLift door off top screws Remove and transfer hinge hole plugsRemove screws from hinges Remove screws from doorRotate outer door Super Wide Side-Swing DoorFlip door over Remove door strike Attach door hingesRemove door strike plug Remove bottom screws Wide Model Side-Swing DoorRemove screws from door Attach door hinges Flip door overRemove and transfer plugs Wide Model Side-Swing Door with Glass Flip door over Rotate outer door Separate inner from outer doorTroubleshooting Remove door strike Remove door strike plugSécurité de la sécheuse Page Outils nécessaires pour toutes les installations Outillage et piècesExigences d’emplacement Outils nécessaires aux installations au gazPièces fournies Pièces nécessairesEspacements d’installation Espacement pour une installationEspacement pour une installation dans un Encastrement ou dans un placardSpécifications électriques ’est à l’utilisateur qu’incombe la responsabilité deInstallation des pieds de nivellement Spécifications de l’alimentation en gazPréparer la sécheuse pour les pieds de nivellement Visser dans les pieds de nivellementCanalisation de gaz Exigences concernant le raccordement au gazCanalisation d’arrivée de gaz de la sécheuse Caractéristiques d’alimentation du brûleurAltitudes supérieures à 10 000 pieds 3 048 m Épreuve sous pression de l’alimentation en gazExigences concernant l’evacuation Installations d’évacuation recommandées Installations d’évacuation facultativesInstallations alternées pour dégagements étroits Planification du système d’évacuationTableau des systèmes d’évacuation Dispositions spéciales pour les maisons mobilesDéterminer l’itinéraire d’acheminement du conduit Installation du circuit d’évacuation Raccordement au gazDéplacer la sécheuse à son emplacement final Régler l’aplomb de la sécheuseRaccorder le conduit d’évacuation La bouche d’évacuationAchever l’installation liste de Vérification Inversion du sens de l’ouverture De la porte facultatifSi la sécheuse ne démarre pas, vérifier ce qui suit Ôter les vis inférieures Soulever la porte pour la dégager des vis supérieuresModèle large avec porte à grande ouverture latérale de Contrôler l’alignement de la gâche de la porte Placer une serviette sur la sécheusePorte à très grande ouverture latérale de Ôter les vis des charnières Ôter les vis du panneau de porteFaire pivoter la porte externe Retourner la porteRetirer la gâche de porte Retirer le bouchon d’obturation de la gâche de porte Modèle large avec porte à ouverture latérale deÔter les vis des charnières Retourner la porte Fixer les charnières de porte’aide des mêmes 4 vis Placer une serviette sur la sécheuse Faire pivoter la porte externe Dépannage W10115228B W10115229B-SP