Whirlpool W10115229B-SP Electrical Requirements, Install Leveling Legs, It is your responsibility

Page 7

Electric Dryer Power Hookup – Canada Only

Electrical Requirements

It is your responsibility:

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in conformance with the Canadian Electrical Code, C22.1-latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.

To supply the required 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.

This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft. (1.52 m) in length. Be sure wall receptacle is within reach of dryer’s final location.

4-wire receptacle (14-30R)

Do not use an extension cord.

If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 8579325. For further information, please reference the “Assistance or Service” section of the “Dryer User Instructions.”

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

Install Leveling Legs

1. Prepare dryer for leveling legs

To avoid damaging floor, use a large flat piece of cardboard from dryer carton; place under entire back edge of dryer. Firmly grasp dryer body (not console panel) and gently lay dryer down on cardboard.

7

Image 7
Contents Gaz É.-U. et Canada et Électrique Canada uniquement Table of Contents Table des matièresDryer Safety Page Tools needed for gas installations Tools needed for all installationsTools and Parts You will need Location RequirementsParts supplied Parts neededInstallation spacing for recessed area or closet Installation clearancesWide Models Dryer Dimensions Installation SpacingIt is your responsibility Install Leveling LegsElectrical Requirements Prepare dryer for leveling legsScrew in leveling legs Gas Supply RequirementsBurner input requirements Dryer gas pipeVenting Requirements Plan Vent System Recommended exhaust installationsOptional exhaust installations Alternate installations for close clearancesInstall exhaust hood Install Vent SystemVent System Chart Vent System Chart Wide Long Vent Models OnlyConnect Vent Make Gas ConnectionReverse Door Swing Optional Complete Installation ChecklistTighten and adjust leveling legs Level DryerRemove and transfer hinge hole plugs Place towel on dryerRemove bottom screws Lift door off top screwsSuper Wide Side-Swing Door Remove screws from hingesRemove screws from door Rotate outer doorAttach door hinges Flip door over Remove door strikeWide Model Side-Swing Door Remove door strike plug Remove bottom screwsFlip door over Remove screws from door Attach door hingesRemove and transfer plugs Wide Model Side-Swing Door with Glass Separate inner from outer door Flip door over Rotate outer doorRemove door strike Remove door strike plug TroubleshootingSécurité de la sécheuse Page Outillage et pièces Outils nécessaires pour toutes les installationsPièces nécessaires Exigences d’emplacementOutils nécessaires aux installations au gaz Pièces fourniesEncastrement ou dans un placard Espacements d’installationEspacement pour une installation Espacement pour une installation dans un’est à l’utilisateur qu’incombe la responsabilité de Spécifications électriquesVisser dans les pieds de nivellement Installation des pieds de nivellementSpécifications de l’alimentation en gaz Préparer la sécheuse pour les pieds de nivellementCaractéristiques d’alimentation du brûleur Canalisation de gazExigences concernant le raccordement au gaz Canalisation d’arrivée de gaz de la sécheuseÉpreuve sous pression de l’alimentation en gaz Altitudes supérieures à 10 000 pieds 3 048 mExigences concernant l’evacuation Planification du système d’évacuation Installations d’évacuation recommandéesInstallations d’évacuation facultatives Installations alternées pour dégagements étroitsDispositions spéciales pour les maisons mobiles Tableau des systèmes d’évacuationDéterminer l’itinéraire d’acheminement du conduit Raccordement au gaz Installation du circuit d’évacuationLa bouche d’évacuation Déplacer la sécheuse à son emplacement finalRégler l’aplomb de la sécheuse Raccorder le conduit d’évacuationInversion du sens de l’ouverture De la porte facultatif Achever l’installation liste de VérificationSi la sécheuse ne démarre pas, vérifier ce qui suit Soulever la porte pour la dégager des vis supérieures Ôter les vis inférieuresModèle large avec porte à grande ouverture latérale de Placer une serviette sur la sécheuse Contrôler l’alignement de la gâche de la portePorte à très grande ouverture latérale de Retourner la porte Ôter les vis des charnièresÔter les vis du panneau de porte Faire pivoter la porte externeRetirer la gâche de porte Modèle large avec porte à ouverture latérale de Retirer le bouchon d’obturation de la gâche de porteFixer les charnières de porte Ôter les vis des charnières Retourner la porte’aide des mêmes 4 vis Placer une serviette sur la sécheuse Faire pivoter la porte externe Dépannage W10115228B W10115229B-SP