Installation Clearances

A water heater set to deliver 120°F (49°C) water to the washer.

Hot and cold water faucets located within 4 ft (1.2 m) of the hot and cold water fill valves, and water pressure of 5-100 psi (34.5-689.6 kPa).

The washer/dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Do not operate your washer in temperatures at or below

32ºF (0ºC). Some water can remain in the washer and can cause damage in low temperatures. See “Washer/Dryer Care” in the Washer/Dryer User Instructions for winterizing information.

Do not operate your dryer in temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times.

Check code requirements. Some codes limit, or do not permit, installation of the washer/dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.

Installation Clearances

The location must be large enough to allow the dryer door to open fully.

Washer/Dryer Dimensions

71 58"

23 34"

(1819 mm)

 

(603 mm)

32 14 "

(819 mm)

*32"

 

(813 mm)

27"

 

(686 mm)

*Most installations require a minimum 5" (127 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this washer/dryer. This washer/dryer has been tested for spacing of 0" (0 mm) clearance on the sides. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door, and floor moldings.

Additional spacing on all sides of the washer/dryer is recommended to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

6"

3"

(152 mm)

(76 mm)

48 in.2

 

(310 cm2)

 

24 in.22

3"

(155 cm )

(76 mm)

 

 

 

 

 

27"

 

 

 

 

 

 

 

 

 

 

 

 

 

1"

 

 

 

1"

 

 

1"*

32"

 

 

5"**

(25 mm)

(686 mm)

(25 mm)

(25 mm) (813 mm)

 

(127 mm)

 

 

 

 

A

 

 

 

 

 

 

B

 

 

 

 

C

A. Recessed area

B. Side view - closet or confined area

C. Closet door with vents

*Required spacing

**Rear clearance may be 1" (25 mm) when house exhaust system is lined up directly with dryer exhaust.

Mobile Home - Additional Installation Requirements

This washer/dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

Metal exhaust system hardware, which is available for purchase from your dealer.

Mobile Home Installation Kit Part Number 346764. See “Tools and Parts” section for information on ordering.

Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

DrainSystem

The washer/dryer can be installed using the standpipe drain system (floor or wall), the laundry tub drain system, or the floor drain system. Select the drain hose installation method you need. See “Alternate Parts.”

Standpipe drain system - wall or floor (views A & B)

The standpipe drain requires a minimum diameter standpipe of

2" (51 mm). The minimum carry-away capacity can be no less than 17 gal. (64 L) per minute. A 2" (51 mm) diameter to 1" (25 mm) diameter standpipe adapter kit is available. See “Alternate Parts.”

The top of the standpipe must be at least 39" (991 mm) high and no higher than 96" (2.4 m) from the bottom of the washer.

39"

(991 mm)

AB

4

Image 4
Contents WASHER/DRYER SAFETY DANGER WARNING2769CMGASWASHER/DRYER INSTALLATIONINSTRUCTIONS INSTRUCTIONSD’INSTALLATION LAVEUSE/SÉCHEUSEÀGAZ DE2769CMWHAT TO DO IF YOU SMELL GAS Do not try to light any appliance ToolsandParts AlternatePartsLocationRequirements INSTALLATIONINSTRUCTIONSDrainSystem Installation ClearancesWasher/Dryer Dimensions Installation spacing for recessed area or closet installationElectricalRequirementsGasSupplyRequirements GROUNDING INSTRUCTIONSSAVE THESE INSTRUCTIONS Laundry tub drain system view CVentingRequirements Gas supply pressure testingIf using an existing vent system Vent materialRemoveShippingStrap Excessive Weight HazardUse two or more people to move and install washer/dryer Rigid metal ventInstallLevelingLegs ConnecttheDrainHoseConnecttheInletHoses Install the front leveling feetSecuretheDrainHose Clear the water linesConnect the inlet hoses to the washer If you are working in a closet or recessed areaPlanVentSystem Recommended exhaust installationsOptional exhaust installations Alternate installations for close clearancesInstallVentSystem LevelWasher/DryerMakeGasConnection Vent system chartConnectVent CompleteInstallationIf the dryer will not start, check the following SÉCURITÉDELALAVEUSE/SÉCHEUSE DANGER AVERTISSEMENTQUE FAIRE DANS LE CAS D’UNE ODEUR DE GAZ INSTRUCTIONSD’INSTALLATION Exigencesd’emplacementAVERTISSEMENT OutillageetpiècesInstallation dans une maison mobile - autres exigences Espacements d’installationDimensions de la laveuse/sécheuse Systèmedevidange SpécificationsélectriquesSystème de vidange avec évier de buanderie illustration C Système de vidange par le plancher illustration DSpécificationsdel’alimentationengaz Type de gaz Gaz naturelConversion au gaz de pétrole liquéfié Un technicien qualifié doit effectuer la conversionExigencesconcernantl’évacuation Matériel pour l’évacuationRisque d’incendie Utiliser un conduit d’évacuation en métal lourd Ne pas utiliser un conduit d’évacuation en plastiqueInstallationdespiedsdenivellement Enleverlasangled’expéditionRaccordementdutuyaudevidange Installation des pieds de nivellement avantRaccordementdestuyauxd’alimentation Pour utilisation avec vidange par le plancherConnecter les tuyaux d’alimentation aux robinets d’eau Nettoyer les conduites d’eauImmobilisationdutuyaudevidange Planificationdusystèmed’évacuationInstallations d’évacuation recommandées Installations d’évacuation facultativesAutres installations où le dégagement est réduit Dispositions spéciales pour les installations dans une maison mobileTableau des systèmes d’évacuation Déterminer l’itinéraire d’acheminement du conduitNivellementdelalaveuse/sécheuse Installationdusystèmed’évacuationRaccordementàlacanalisationdegaz Raccordement du conduitd’évacuation Acheverl’installationSi la sécheuse ne démarre pas, vérifier ce qui suit Page Page W10222381A 2008Benton Harbor, Michigan 10/08