Whirlpool Gas Washer/Dryer InstallVentSystem, LevelWasher/Dryer, MakeGasConnection, Number of

Page 11
Determine vent length and elbows needed for best drying performance

Determine vent length and elbows needed for best drying performance

Use the Vent system chart below to determine type of vent material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

The Vent system chart provides venting requirements that will help to achieve the best drying performance.

Vent system chart

NOTE: Side exhaust installations add a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.

Number of

Type of Vent

Box or

Angled

90º turns

 

Louvered

hoods

or elbows

 

hoods

 

 

 

 

 

 

0

Rigid metal

37

ft (11.3 m)

35 ft (10.7 m)

 

 

 

 

 

1

Rigid metal

32

ft (9.7 m)

27 ft (8.2 m)

 

 

 

 

 

2

Rigid metal

24

ft (7.3 m)

19 ft (5.8 m)

InstallVentSystem

1.Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.

2.Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp.

3.Run vent to dryer location. Use the straightest path possible. See “Determine vent path” in “Plan Vent System.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into the interior of the vent to secure the vent, because they can catch lint.

LevelWasher/Dryer

Properly leveling your washer/dryer avoids excessive noise and vibration.

1.Check the levelness of the washer/dryer by placing a level on the top edge of the washer, first side to side, then front to back.

2.If the washer/dryer is not level, prop up the front with the wood block and adjust the feet up or down as necessary. Remove wood block.

3.Tilt the washer/dryer forward until the rear of the washer/dryer is at least 4" (102 mm) off the floor. You may hear the self- adjusting rear feet click into place. Lower the washer/dryer to the floor. Check the levelness of the washer/dryer with a level as shown above.

If washer/dryer will not level, recheck rear leveling legs for free movement as described in the “Install Leveling Legs” section. Repeat until the washer/dryer is level.

NOTE: It may be necessary to level the washer/dryer again after it is moved into its final location.

4.After the washer/dryer is in its final location and is level, use an adjustable or open-end wrench to turn the nuts on the front feet tightly against the washer cabinet.

If the nuts are not tight against the washer cabinet, the washer/dryer may vibrate.

MakeGasConnection

1.Remove the red cap from the flexible gas connector.

2.Remove the ½" NPT adapter from the flexible gas connector (it will be necessary to use two adjustable wrenches).

3.Install the adapter on the ½" rigid gas supply pipe using pipe- joint compound.

AB Vent system chartNumber of

C Type of VentBox or D Angled E 90º turnsLouvered

A.½" rigid gas supply pipe

B.Use pipe-joint compound.

C.½" NPT adapter

D.Do not use pipe-joint compound.

E.Flexible gas connector

NOTE: For LP gas connections, you must use pipe-joint compound resistant to the action of LP gas. Do not use TEFLON®† tape.

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

11

Image 11
Contents INSTRUCTIONSD’INSTALLATION LAVEUSE/SÉCHEUSEÀGAZ DE2769CM WASHER/DRYER SAFETYDANGER WARNING 2769CMGASWASHER/DRYER INSTALLATIONINSTRUCTIONSWHAT TO DO IF YOU SMELL GAS Do not try to light any appliance INSTALLATIONINSTRUCTIONS ToolsandPartsAlternateParts LocationRequirementsInstallation spacing for recessed area or closet installation DrainSystemInstallation Clearances Washer/Dryer DimensionsLaundry tub drain system view C ElectricalRequirementsGasSupplyRequirementsGROUNDING INSTRUCTIONS SAVE THESE INSTRUCTIONSVent material VentingRequirementsGas supply pressure testing If using an existing vent systemRigid metal vent RemoveShippingStrapExcessive Weight Hazard Use two or more people to move and install washer/dryerInstall the front leveling feet InstallLevelingLegsConnecttheDrainHose ConnecttheInletHosesIf you are working in a closet or recessed area SecuretheDrainHoseClear the water lines Connect the inlet hoses to the washerAlternate installations for close clearances PlanVentSystemRecommended exhaust installations Optional exhaust installationsVent system chart InstallVentSystemLevelWasher/Dryer MakeGasConnectionIf the dryer will not start, check the following CompleteInstallationConnectVent DANGER AVERTISSEMENT SÉCURITÉDELALAVEUSE/SÉCHEUSEQUE FAIRE DANS LE CAS D’UNE ODEUR DE GAZ Outillageetpièces INSTRUCTIONSD’INSTALLATIONExigencesd’emplacement AVERTISSEMENTDimensions de la laveuse/sécheuse Espacements d’installationInstallation dans une maison mobile - autres exigences Système de vidange par le plancher illustration D SystèmedevidangeSpécificationsélectriques Système de vidange avec évier de buanderie illustration CUn technicien qualifié doit effectuer la conversion Spécificationsdel’alimentationengazType de gaz Gaz naturel Conversion au gaz de pétrole liquéfiéNe pas utiliser un conduit d’évacuation en plastique Exigencesconcernantl’évacuationMatériel pour l’évacuation Risque d’incendie Utiliser un conduit d’évacuation en métal lourdInstallation des pieds de nivellement avant InstallationdespiedsdenivellementEnleverlasangled’expédition RaccordementdutuyaudevidangeNettoyer les conduites d’eau Raccordementdestuyauxd’alimentationPour utilisation avec vidange par le plancher Connecter les tuyaux d’alimentation aux robinets d’eauInstallations d’évacuation facultatives ImmobilisationdutuyaudevidangePlanificationdusystèmed’évacuation Installations d’évacuation recommandéesDéterminer l’itinéraire d’acheminement du conduit Autres installations où le dégagement est réduitDispositions spéciales pour les installations dans une maison mobile Tableau des systèmes d’évacuationRaccordementàlacanalisationdegaz Installationdusystèmed’évacuationNivellementdelalaveuse/sécheuse Si la sécheuse ne démarre pas, vérifier ce qui suit Acheverl’installationRaccordement du conduitd’évacuation Page Page 10/08 W10222381A2008 Benton Harbor, Michigan