Programmable functions

Altering the volume of the buzzer

The buzzer has two volumes.

Follow steps ￿ to ￿ to programme and store in memory.

Before you begin, first ensure that:

The tumble dryer is switched off.

The door is closed.

￿Press the Start/Stop button and keep it pressed in whilst carrying out steps

￿-￿.

￿Press the ￿￿ button in.

Wait until the indicator light for the Start/ Stop button lights up constantly . . .

￿. . . and then release the Start/Stop button.

￿Press the Low temperature button twice.

The Low temperature indicator light will briefly flash on and off four times.

P and 0 (default setting) will flash alternately in the display.

The number which appears alternately in the display with P means:

0Normal buzzer (Default setting)

ILoud buzzer

(The Automatic plus indicator light will also flash)

￿Pressing the Start/Stop button switches from one to the other.

￿Switch the dryer off with the ￿￿ button.

The setting you have selected is now stored in memory. You can change it again at any time.

47

Image 47
Contents Operating instructions For condenser tumble dryer T 8822 C Energy saving tips Caring for the environmentDisposal of the packing material Disposal of your old applianceContents Contents Correct application Safety with childrenTechnical safety Correct use Accessories Control panel Operating the tumble dryerFollowing are also selected via the display Programme duration / Estimated time remainingDisplay shows Ironing Garment care label symbolsTips on drying DryingTurn on the tumble dryer How to dry correctlyBrief instructions Sort the laundryDrying level programmes Select any Extra options / Delay startSelect a programme Before the end of a programme Remove the laundry when the programme has finishedStart the programme Extra options Extra options / Delay startDelay start Delicates Max. load 2.5 kg Normal, Hand iron Programme chartCottons Max. load 7 kg Extra dry, Normal Hand iron**, Machine ironManufacturer as being suitable for use on membrane Woollens handcare Max. load 2 kgProofing Max. load 2.5 kg Normal Only use proofing agents which are stated byGentle smoothing Max. load 1 kg Shirts Max. load 2 kg Normal, Hand ironCool air Max. load 7 kg Warm air Max. load 7 kgAdding or removing laundry after a programme has started Altering Delay startChanging the programme sequence Once a programme has startedTo deactivate the lock Electronic system lockTo activate the lock Emptying the condensed water container Cleaning and careCleaning them whilst dry Cleaning the fluff filtersCleaning them with water Cleaning the tumble dryer Removing the condenser unit Cleaning the condenser unitChecking the condenser unit Checking and cleaning the condenser unit housing Check and fault messages Problem solving guideBuzzer sounds To switch off the indicator Light Problem Possible cause RemedyAirways indicator To switch off the indicatorProgrammes do not Indicators for theseCool air programmes Will not startAn unsatisfactory drying result Goes on too long or Other problemsProblem Possible cause Remedy Drying process Even switches offDryer after Problem Possible cause Remedy Water leaks fromBeen cleaned Power cutChanging the lamp Optional accessories After Sales serviceFuture updates PC Appliance guaranteeFront view InstallationReplacing the lid Installation siteTransporting the dryer to its installation site Rear viewWasher-dryer stack Before moving the tumble dryer again e.g. when moving houseLevelling the appliance Room ventilationArranging the drain hose External condensed water outletGeneral notes External drainage via a sink or gully Installation conditions requiring a non-return valveInstallation Electrical connection U.K Non-rewireable plugs BSElectrical connection Woollens handcare Consumption dataTechnical data Extending the range of the drying levels Programmable functionsHours anti-crease Anti-crease settingAnti-crease deactivated Hour anti-crease Normal buzzer Default setting Loud buzzer Altering the volume of the buzzerMemory function Memory deactivated default setting Memory activatedCooling down time will be ten minutes longer Extending the cooling down timeFollow steps to to programme and store in memory Default setting Clean out airways indicatorKeypad tone Default setting Adjusted for very soft water Adjusting the dryers electronics for very soft waterPage Page Page Alteration rights reserved/1409 Nr 483 560