57
WFR 2460 Service Tips -- Test Programram (1)(1)
The WFR 2460UC washers have test programs enabling the washers to
Rotate selector switch to Off position. Press & hold Menu & Select buttons (located under display), then rotate selector switch ccw to
Permanent Press Cold
until display comes on. See next page for error codes.
HINT: Push Menu button to scroll through all tests to select desired test. Red light on Start/ Pause button flashes to show tests can be selected. When tests are started, red light stays on constantly. Push Menu to exit test & select more tests.
Rotate selector switch to Off position.
NOTE: “ ” = drum speed (RPM) & “n” = pressure switch reading.
Cold water valve
Hot water valve
Water levels
…...
(cw)
(ccw)
1st Edition/Revision 5 (1/20/04)