Alliance Laundry Systems 18, 75 Water Connection, Water Supply Information Model 100 135 165 200

Page 48

Installation

Water Connection

WARNING

To avoid personal injury, recommended inlet water temperature should be no higher than 125° Fahrenheit (51° Celsius).

W709

The 18-135 models are delivered with hoses with 3/4 inch hose connectors. The 165 model is delivered with 3 x 1 inch and 1 x 3/4 inch hose connectors. These hoses fit the water inlet valves of the machine and the main water inlet taps. To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 30-85 psi (2-5.7 bar). If the pressure is too low, the cycle time will increase considerably. In case of boiler fed machines, a maximum of hot water of 194°F (90°C) should be available:

Connections should be supplied by a hot and a cold water line per national and local codes.

To connect water service to machine with rubber hoses, use the following procedure:

1.Before installing hoses, flush the water system for at least two minutes.

2.Check filters in the washer-extractor’s inlet hoses for proper fit and cleanliness before connecting.

3.Hang the hoses in a large loop, do not allow them to kink.

If additional hose length is needed use flexible hoses with screen filters. Each hose should have a screen filter installed to keep rust and other foreign particles out of the water inlet valves.

Pressure of 30-85 psi (2-5.7 bar) provides best performance. Although the washer-extractor will function at lower pressures, increased fill times will occur with some loss of supply flushing.

Suitable air cushions should be installed in supply lines to prevent “hammering.”

Water Supply Information

Model

18

25

33

35

40

55

75

100

135

165

200

 

 

 

 

 

 

 

 

 

 

 

 

Water inlet

0.75 in.

0.75 in.

0.75 in.

0.75 in.

0.75 in.

0.75 in.

0.75 in.

0.75 in.

0.75 in.

1.0 in.

0.75 and

connection

(19 mm)

(19 mm)

(19 mm)

(19 mm)

(19 mm)

(19 mm)

(19 mm)

(19 mm)

(19 mm)

(25 mm)

1.0 in.

size

 

 

 

 

 

 

 

 

 

 

(19 and

 

 

 

 

 

 

 

 

 

 

 

25 mm)

 

 

 

 

 

 

 

 

 

 

 

 

Number of

3

3

3

3

3

3

3

4

4

4

4

water inlets

 

 

 

 

 

 

 

 

 

 

 

(standard)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recom-

30-85psi

30-85 psi

30-85 psi

30-85psi

30-85 psi

30-85 psi

30-85 psi

30-85 psi

30-85 psi

30-85 psi

30-85 psi

mended

(2-5.7

(2-5.7

(2-5.7

(2-5.7

(2-5.7

(2-5.7

(2-5.7

(2-5.7

(2-5.7

(2-5.7

(2-5.7

pressure

bar)

bar)

bar)

bar)

bar)

bar)

bar)

bar)

bar)

bar)

bar)

 

 

 

 

 

 

 

 

 

 

 

 

Inlet flow

5.3 gal/

5.3 gal/

5.3 gal/

5.3 gal/

5.3 gal/

12 gal/

12 gal/

12 gal/

12 gal/

25 gal/

25 gal/

capacity

min

min

min

min

min

min

min

min

min

min

min

 

(20 l/

(20 l/

(20 l/

(20 l/

(20 l/

(45 l/

(45 l/

(45 l/

(45 l/

(95 l/

(95 l/

 

min)

min)

min)

min)

min)

min)

min)

min)

min)

min)

min)

 

 

 

 

 

 

 

 

 

 

 

 

Table 5

46

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9001000

Image 48
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsSafety Information Safety Decals Operator Safety Introduction Model Identification100 135 165 200 Introduction Replacement Parts Customer ServiceNameplate Location Introduction Model Number Familiarization Guide 0001General Specifications Model Overall Dimensions Weight and Shipping InformationWash Cylinder Information Door Opening InformationCylinder Speeds Centrifugal Force DataBalance Detection Direct Steam Heating OptionalWeight and Shipping Information RPM Specifications and Dimensions Main Switch Electrical Power Inputs Flushing Supply Dispenser Steam Connection Input Optional 88 mm 220 mm Mm 53.07 in mm 50 mm 34 mm Model 1168 mm 1575 mm 33.6 1010 mm 305 mm 360 mm 56.5 mm Installation Recommended Minimum Clearances Model 100 135 165 200Installation Floor Load Data Model 100 135 165 200Mechanical Installation Important Drawing is not to scalePound 34 mm 22 mm 26.18 665 mm 26.77 50 mm 680 mm 30.71 780 mm 712 mm 34 mm 22 mm 30.12 765 mm 898 mm 42.52 47.24 1200 mm 40 mm 1200 mm 42.5 mm 1300 mm 33 mm 44.8 660 mm 55 mm 30.31 782 mm 45 mm Mounting Bolt Installation If Required Removing the Transport Brackets Front Rear 40 Models Drain Connection Rear of MachineModel 100 135 165 200 Minimum Drain ID Model Number of MachinesWater Connection Water Supply Information Model 100 135 165 200Electrical Installation Do not use a phase adder on any variable- speed machineCycle Phase Wire Full Load Amps Installation Electrical Connection Remote Liquid Supply ConnectionSteam Requirements Steam Heat Option Only Steam Supply Information 18-75 100/135 165/200Supply Programming Table Example Pumps 24V ~ Out-of-Balance Switch Automatic LubricatorControl Function Test Machine