Alliance Laundry Systems 100, 75, 40, 33, 135, 165, 200, 18, 55 Mounting Bolt Installation If Required

Page 43

Mounting Bolt Installation (If Required)

 

1

 

 

2

 

 

3

 

6 in.

 

 

(152 mm)

 

 

 

4

CFS485N

 

 

 

 

CFS485N

1

Base Frame

 

2

Bolt

 

3

Washer

 

4

Anchor Bolt/Plug

 

Figure 28

After the concrete has cured and the anchors are installed, proceed as follows:

1.Place the washer-extractor adjacent to the foundation. Do not attempt to move it by pushing on the sides. Always insert a pry bar or other device under the bottom of the frame of the washer-extractor to move it.

2.Place the washer-extractor carefully over the anchors.

Installation

3.Put bolts through the machine in the anchors and fasten them. (For the 18, 25, and 35 models, the diameter of the bolt must be minimum 1/2-13 or 12 mm; for the 33, 40, 55, 75, 100, 135, 165 and 200 models, the diameter of the bolt must be minimum 5/8-11 or 16 mm.)

4.To level machine, fill the spaces between the machine base and floor with machinery grout. Grout completely under all frame members.

Remove front and rear panels to gain access to all frame members. Force grout under the machine base until all voids are filled.

5.Remove the spacers carefully, allowing the machine to settle into the wet grout.

6.Position washers and locknuts on machinery anchor bolts and finger-tighten to machine base.

7.After the grout is completely dry, tighten the locknuts by even increments – one after the other – until all are tightened evenly and the machine is fastened securely to the floor.

8.Remove the four red transport brackets which secure the moving components of the machine during shipping. Refer to Figures 29, 31 and 32 for typical transport bracket locations.

9001000

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

41

Image 43
Contents Washer-Extractors Page Contents Important Safety Instructions Explanation of Safety MessagesSafety Information Safety Decals Operator Safety Model Identification Introduction100 135 165 200 Introduction Customer Service Replacement PartsNameplate Location 0001 Introduction Model Number Familiarization GuideDoor Opening Information General Specifications Model Overall DimensionsWeight and Shipping Information Wash Cylinder InformationDirect Steam Heating Optional Cylinder SpeedsCentrifugal Force Data Balance DetectionWeight and Shipping Information RPM Specifications and Dimensions Main Switch Electrical Power Inputs Flushing Supply Dispenser Steam Connection Input Optional 88 mm 220 mm Mm 53.07 in mm 50 mm 34 mm Model 1168 mm 1575 mm 33.6 1010 mm 305 mm 360 mm 56.5 mm Recommended Minimum Clearances Model 100 135 165 200 InstallationFloor Load Data Model 100 135 165 200 InstallationImportant Drawing is not to scale Mechanical InstallationPound 34 mm 22 mm 26.18 665 mm 26.77 50 mm 680 mm 30.71 780 mm 712 mm 34 mm 22 mm 30.12 765 mm 898 mm 42.52 47.24 1200 mm 40 mm 1200 mm 42.5 mm 1300 mm 33 mm 44.8 660 mm 55 mm 30.31 782 mm 45 mm Mounting Bolt Installation If Required Removing the Transport Brackets Front Rear 40 Models Rear of Machine Drain ConnectionMinimum Drain ID Model Number of Machines Model 100 135 165 200Water Supply Information Model 100 135 165 200 Water ConnectionDo not use a phase adder on any variable- speed machine Electrical InstallationCycle Phase Wire Full Load Amps Installation Remote Liquid Supply Connection Electrical ConnectionSteam Supply Information 18-75 100/135 165/200 Steam Requirements Steam Heat Option OnlySupply Programming Table Example Pumps 24V ~ Automatic Lubricator Out-of-Balance SwitchMachine Control Function Test