Alliance Laundry Systems 33, 75, 40, 100, 135 Electrical Connection, Remote Liquid Supply Connection

Page 52

Installation

Electrical Connection

Remove the cover plate at the back of the machine. Using copper conductors only, connect the power cable to the connectors. Refer to the instructions listed on the machine’s decal on how to connect the machine.

After electrical installation is complete, run the machine through a test cycle and check for clockwise basket rotation during the extract step. If rotation is not clockwise, disconnect the power from the machine and have a qualified electrician reverse any 2 motor leads at the AC drive terminal block.

Remote Liquid Supply Connection

Chemical Injection Supply System

WARNING

Dangerous Chemicals. May damage eyes and skin. Wear eye and hand protection when handling chemicals; always avoid direct contact with raw chemicals. Read the manufacturer’s directions for accidental contact before handling chemicals. Ensure an eye-rinse facility and an emergency shower are within easy reach. Check at regular intervals for chemical leaks.

W363

Undiluted chemical dripping can damage the machine. Therefore, all chemical supply dispenser pumps should be mounted below the washer’s injection point. All dispenser tubing should also run below the injection point. Loops do not prevent drips if these instructions are not followed. Failure to follow these instructions could damage the machine and void the warranty.

CONNECTION OF THE LIQUID SUPPLY HOSES

CFS492N

Figure 34

A connection has been placed at the back of the machine. There are nine holes in this connection, through each of which a liquid supply hose can be connected.

CAUTION

Drill out plugs and nipples before making supply hose connection. Failure to do so can cause buildup of pressure and risk a tubing rupture.

W491

50

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9001000

Image 52
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsSafety Information Safety Decals Operator Safety Introduction Model Identification100 135 165 200 Introduction Customer Service Replacement PartsNameplate Location Introduction Model Number Familiarization Guide 0001General Specifications Model Overall Dimensions Weight and Shipping InformationWash Cylinder Information Door Opening InformationCylinder Speeds Centrifugal Force DataBalance Detection Direct Steam Heating OptionalWeight and Shipping Information RPM Specifications and Dimensions Main Switch Electrical Power Inputs Flushing Supply Dispenser Steam Connection Input Optional 88 mm 220 mm Mm 53.07 in mm 50 mm 34 mm Model 1168 mm 1575 mm 33.6 1010 mm 305 mm 360 mm 56.5 mm Installation Recommended Minimum Clearances Model 100 135 165 200Installation Floor Load Data Model 100 135 165 200Mechanical Installation Important Drawing is not to scalePound 34 mm 22 mm 26.18 665 mm 26.77 50 mm 680 mm 30.71 780 mm 712 mm 34 mm 22 mm 30.12 765 mm 898 mm 42.52 47.24 1200 mm 40 mm 1200 mm 42.5 mm 1300 mm 33 mm 44.8 660 mm 55 mm 30.31 782 mm 45 mm Mounting Bolt Installation If Required Removing the Transport Brackets Front Rear 40 Models Drain Connection Rear of MachineModel 100 135 165 200 Minimum Drain ID Model Number of MachinesWater Connection Water Supply Information Model 100 135 165 200Electrical Installation Do not use a phase adder on any variable- speed machineCycle Phase Wire Full Load Amps Installation Electrical Connection Remote Liquid Supply ConnectionSteam Requirements Steam Heat Option Only Steam Supply Information 18-75 100/135 165/200Supply Programming Table Example Pumps 24V ~ Out-of-Balance Switch Automatic LubricatorControl Function Test Machine