7. TROUBLESHOOTING
7-1. BEFORE PERFORMING SERVICE
1
2
3
4
5
6
Before servicing ask the customer what the trouble is.
Check the adjustments. (Power
Decide service steps referring to disassembly instructions.F1*22TD Then, service and repair.
After servicing, operate the appliance to see whether it works OK or NOT.
| F1*20TD |
1F1*22TD : Press and Hold ‘Temp.’ & ‘Spin’ buttons and then press ‘Power’ button.
F1*20TD : Press and Hold ‘Option’ & ‘Spin’ buttons and then press ‘Power’ button.
2The washer must be empty and the controls must be in the off state.
3Press Power with above two buttons pressed and then buzzer will sound.
4Press the Start/Pause button repeatedly to cycle through the test modes
Pressing number of | Checking Point | Display Status | |
[Start/Pause] button | |||
|
| ||
|
|
| |
None | All lamps turn on |
| |
|
|
| |
1 time | Clockwise spin (right) | Motor rpm (About 47) | |
|
|
| |
2 times | Low speed Spin | Motor rpm (About 590~650) | |
|
|
| |
3 times | High speed Spin | Motor rpm (About 950~1050) : F10**TD(1~9) | |
|
|
| |
|
| Motor rpm (About 1100~1250) : F12**TD(1~9) | |
|
|
| |
|
| Motor rpm (About 1350~1400) : F14**TD(1~9) | |
|
|
| |
4 times | Inlet valve for | Water level frequency (225~265) | |
|
|
| |
5 times | Inlet valve for | Water level frequency (225~265) | |
|
| ||
| Hot inlet valve in case of hot water fill | ||
|
| ||
|
|
| |
6 times | Inlet valve for | Water level frequency (225~265) | |
|
|
| |
7 times | Counterclockwise spin (left) | Motor rpm (About 47) | |
|
|
| |
8 times | A Heater is in operation for 3 sec. | Water Temperature | |
|
|
| |
9 times | Draining pump operation | Water level frequency | |
|
|
| |
10 times | Auto off operation |
| |
|
|
|
7-3. HOW TO KNOW THE WATER LEVEL FREQUENCY
F1*22TD : Press and Hold ‘Temp.’ & ‘Medic Rinse’ buttons simultaneously.
F1*20TD : Press and Hold ‘Intensive’ button.
The digits means water level frequency
ex) 241 : Water level frequency = 241 X 10