PUMP
Pump Outlet Hose
Tub Pump
Bellows
HEATER |
M6 heater nut |
1Remove pump outlet hose.
2Remove tub pump bellows.
3Remove cap (Remaining Hose.)
4Disconnect the wiring.
5Unscrew 2 screws.
6Remove the pump.
•Rating : 220~240V 50HZ 30W
•Resistant : 160~177Ω
1Loosen the M6 heater nut to pull out the heater.
CAUTION
When mounting the heater, be sure to insert the heater into the heater clip on the bottom of the tub.
•Rating : 220~240V 2000W
•Resistant : 24.7~28.0Ω
41