Thermistor (Heating) Error (tE)
Is the Connector connected correctly to the Main PCB and the Thermistor and the Heater? Or is the Harness alright ?
NO
Is the resistance of the Thermistor out of range 44 ~ 53 KΩ at 25°C?
(Page 17)
NO
YES | Reconnect or repair the Connector. | |
Or replace the Harness. | ||
|
YES | Replace the Thermistor. |
Is the resistance of the Heater out of range 24.7 ~ 28.0Ω ? (Page 17)
YES | Replace the Heater. |
NO
Replace the Main PCB.
[Note] Thermistor Spec
S
P
E
C
Temp |
|
| Resistance (kΩ) |
| ||
|
|
|
|
|
| |
| MIN |
| STD |
| MAX | |
|
|
|
| |||
|
|
|
|
|
| |
30 °C | 36.35 |
| 39.45 |
| 42.72 | |
|
|
|
|
|
| |
40 °C | 24.20 |
| 26.05 |
| 27.97 | |
|
|
|
|
|
| |
60 °C | 11.43 |
| 12.12 |
| 12.82 | |
70 °C | 8.088 |
| 8.514 |
| 8.940 | |
|
|
|
|
|
| |
95 °C | 3.544 |
| 3.791 |
| 4.045 | |
|
|
|
|
|
| |
105 °C | 2.617 |
| 2.816 |
| 3.023 | |
|
|
|
|
|
|
|
28