Whirlpool GVW9959K-0 manual Pump Drive Description Water

Page 24

Whitest Whites

This cycle introduces liquid chlorine bleach to the load at the proper time for improved whitening of your heavily soiled white fabrics. Use this cycle to get 13 to 17 minutes of medium speed wash action and high speed final spin. For maximum soil and stain removal, liquid chlorine bleach must be used. The preset cycle wash time is 15 minutes.

 

 

 

 

 

 

 

 

 

PUMP

DRIVE

DRIVE

 

 

 

DESCRIPTION OF

 

 

WATER

 

 

 

MOTOR

MOTOR

MOTOR

DURATION

PHASE

STEP

SEQUENCE

NOTES

 

TEMP

DISPENSER

COMMENT

 

ACTION

ACTION

SPEED

(MIN:SEC)

WASH

1

OPTIONAL FLUFF

19

 

OFF

OFF

 

 

OFF

NUTATE

275

00:08

 

2

STATIC FILL

1,9,19

 

WASH

DETERGENT

PS CONTROLLED

 

OFF

OFF

0

VAR

 

3

SPIN+RECIRC+FILL

1

 

WASH

DETERGENT

PS CONTROLLED

 

RECIRC

SPIN

60

00:25

 

4

SPIN+RECIRC

 

 

WASH

OFF

 

 

RECIRC

SPIN

60

00:05

 

5

NUTATE+RECIRC

 

 

WASH

OFF

 

 

RECIRC

NUTATE

275

00:05

 

6

NUTATE+RECIRC+FILL

1,10

 

WASH

DETERGENT

PS CONTROLLED

 

RECIRC

NUTATE

275

12:55

 

7

PAUSE

11

 

COLD

OFF

 

 

OFF

OFF

0

(00:05)

 

8

STATIC FILL-COLD

5

 

COLD

DETERGENT

TIMED FILL

 

OFF

OFF

0

00:15

 

 

END OF WASH

 

 

 

 

 

 

 

 

 

 

RINSE

9

NEUTRAL DRAIN

 

 

OFF

OFF

RINSING LED ON

 

DRAIN

OFF

0

00:15

 

10

NUTATE+RECIRC+FILL

9

 

COLD

FRESH

PS CONTROLLED

 

RECIRC

NUTATE

275

00:30+

 

11

PAUSE

11

 

COLD

OFF

 

 

OFF

OFF

0

(00:05)

 

12

STATIC FILL-COLD

 

 

COLD

DETERGENT

TIMED FILL

 

OFF

OFF

0

00:17

 

13

BLEACH

3

 

COLD

BLEACH

TIMED FILL

 

OFF

OFF

0

00:03

 

14

NUTATE+RECIRC

 

 

OFF

OFF

 

 

RECIRC

NUTATE

275

03:00

 

15

PAUSE

11

 

COLD

OFF

 

 

OFF

OFF

0

(00:05)

 

16

STATIC FILL-COLD

 

 

COLD

DETERGENT

TIMED FILL

 

OFF

OFF

0

00:30

 

17

NEUTRAL DRAIN

 

 

OFF

OFF

 

 

DRAIN

OFF

0

01:00

 

18

SPIN+DRAIN+FILL

7,8

 

COLD

FRESH

TIMED FILL

 

DRAIN

SPIN

60

02:00

 

19

NUTATE+DRAIN

 

 

OFF

OFF

 

 

DRAIN

NUTATE

275

00:15

 

20

SPIN+DRAIN W/ SUDS

17

 

OFF

OFF

PS CONTROLLED

 

DRAIN

SPIN

500

01:30

 

 

PROFILE

 

 

 

 

 

 

 

 

 

 

 

21

PAUSE

11

 

COLD

OFF

 

 

OFF

OFF

0

(00:05)

EXTRA RINSE

A

STATIC FILL – COLD

7,9

 

COLD

DETERGENT

PS CONTROLLED

 

OFF

OFF

0

VAR

(IF SELECTED)

B

NUTATE + RCRC

 

 

OFF

OFF

 

 

RECIRC

NUTATE

275

00:15

 

C

SPIN + RCRC + FILL

9

 

COLD

FRESH

PS CONTROLLED

 

RECIRC

SPIN

60

00:30+

 

D

NUTATE + RCRC + FILL

9

 

COLD

FRESH

PS CONTROLLED

 

RECIRC

NUTATE

275

00:30+

 

E

NEUTRAL DRAIN

 

 

OFF

OFF

 

 

DRAIN

OFF

0

00:30

END EXTRA R.

F

SPIN + DRAIN

 

 

OFF

OFF

 

 

DRAIN

SPIN

300

00:15

G

NEUTRAL DRAIN

 

 

OFF

OFF

 

 

DRAIN

OFF

0

00:30

 

22

STATIC FILL – COLD

7,9

 

COLD

DETERGENT

PS CONTROLLED

 

OFF

OFF

0

VAR

 

23

NUTATE + RCRC

 

 

OFF

OFF

 

 

RECIRC

NUTATE

275

00:15

 

24

SPIN + RCRC + FILL

9

 

COLD

FRESH

PS CONTROLLED

 

RECIRC

SPIN

60

00:30+

 

25

NUTATE + RCRC + FILL

9

 

COLD

FRESH

PS CONTROLLED

 

RECIRC

NUTATE

275

00:30+

 

26

NEUTRAL DRAIN

 

 

OFF

OFF

 

 

DRAIN

OFF

0

00:30

 

27

SPIN + DRAIN

 

 

OFF

OFF

 

 

DRAIN

SPIN

300

00:15

 

28

NEUTRAL DRAIN

 

 

OFF

OFF

 

 

DRAIN

OFF

0

00:30

 

29

NUTATE + FILL

 

 

COLD

DETERGENT

TIMED FILL

 

OFF

NUTATE

275

00:10

 

30

NUTATE + RCRC + FILL

9

 

COLD

FRESH

PS CONTROLLED

 

RECIRC

NUTATE

275

VAR

 

31

NEUTRAL DRAIN

 

 

OFF

OFF

 

 

DRAIN

OFF

0

00:30

 

32

SPIN + DRAIN

 

 

OFF

OFF

 

 

DRAIN

SPIN

300

00:15

 

33

NUTATE + DRAIN

 

 

OFF

OFF

 

 

DRAIN

NUTATE

275

00:08

 

34

NEUTRAL DRAIN

 

 

OFF

OFF

 

 

DRAIN

OFF

0

00:22

 

35

SPIN + DRAIN W/ CND

14,16

 

OFF

OFF

PS CONTROLLED

 

DRAIN

SPIN

500

00:30

 

36

NUTATE + DRAIN

 

 

OFF

OFF

 

 

DRAIN

NUTATE

275

00:30

 

37

NUTATE + FILL

 

 

COLD

DETERGENT

TIMED FILL

 

OFF

NUTATE

275

00:10

 

38

NUTATE + RCRC + FILL

9

 

COLD

FRESH

PS CONTROLLED

 

RECIRC

NUTATE

275

VAR

 

39

FABRIC SOFTENER

4

 

COLD

FAB SOFT

TIMED FILL

 

OFF

OFF

0

01:00

 

40

SPIN + RCRC + FILL

9

 

COLD

FRESH

PS CONTROLLED

 

RECIRC

SPIN

60

02:00+

 

41

NUTATE+RECIRC

 

 

COLD

OFF

 

 

RECIRC

NUTATE

275

00:05

 

42

NUTATE + RCRC + FILL

9

 

COLD

DETERGENT

PS CONTROLLED

 

RECIRC

NUTATE

275

03:55+

 

43

NEUTRAL DRAIN

 

 

OFF

OFF

 

 

DRAIN

OFF

0

00:30

SPIN & FLUFF

44

SPIN + DRAIN W/CND

14,16

 

OFF

OFF

PS CONTROLLED

 

DRAIN

SPIN

500

00:30+

 

45

SPIN + DRAIN + FILL

8

 

COLD

FRESH

TIMED FILL

 

DRAIN

SPIN

500

00:30

 

46

SPIN + DRAIN W/CND

14

 

OFF

OFF

PS CONTROLLED

 

DRAIN

SPIN

500

00:15+

 

47

NUTATE + DRAIN

 

 

OFF

OFF

 

 

DRAIN

NUTATE

275

00:15

 

48

SPIN + DRAIN W/CND

6,13,14,16

 

OFF

OFF

PS CONTROLLED

 

DRAIN

SPIN

800

05:00+

 

 

 

 

 

(OR

(OR FRESH 5 SEC

 

 

 

 

 

 

 

 

 

 

 

WARM 5

– SEE NOTE 8)

 

 

 

 

 

 

 

 

 

 

 

SEC)

 

 

 

 

 

 

 

 

49

FLUFF

15

 

OFF

OFF

 

 

OFF

NUTATE

275

00:30

 

50

PLATE LEVEL

15

 

OFF

OFF

 

 

OFF

SPIN

60

00:05

END OF CYCLE

 

END OF CYCLE (EOC)

 

 

OFF

OFF

 

 

OFF

OFF

 

42:53

END OF CYCLE

 

EOC W/ 2ND RINSE

 

 

OFF

OFF

 

 

OFF

OFF

 

45:23

20

Image 24
Contents Page Introduction Table of Contents Safety MODEL/SERIAL Number Plate Serial Number DesignatorModel Number Designator Model Number G V W 9 9 5 9 K Q Installation ConsiderationsSection ONE For a permanently connected washerTools needed Parts Supplied DrainSystem ConnectingtheDrainHose InstallationChecklist Use&CareInformation Theory of Operation Section TWONutation Control PanelOperational Cycle Default Wash and Spin Option DescriptionsSoil Level Water Temp Assured Water TempATC Thresholds Whitest WhitesEnd of Cycle Signal Additional OptionsMachine Controller Motor ControllerDrive Motor Peekaboo Mode LevelerUniversal Joint Interlock Switches Drive SystemShield Capacitor Pressure Switches LOG Valve AssemblyOPR FLD Recirculation and Drain Water Pump/Pump MotorOuter Tub RecirculationDrain Changing Cycles and OptionsChanging Cycles after pressing Start Changing Options after pressing StartOperational Cycle Notes Drive Motor Notes Pump Drive Description Water Description Water Pump Drive Duration Description Water Pump Drive Pump Drive Description Action Speed Pump Drive Description Delicate/Casual SPIN+RECIRC+FILL Wash Detergent PS Controlled Recirc Spin Handwash Garments are labelled Hand Wash becauseSoak Cycle Extra RinseExtend Spin Cycle When to use Rinse & Spin To use or change Rinse & Spin settingsSuds Lock Detection/Cleanout Rinse & SpinComponent Access Special TOOLS/PARTS Required for ServiceSection Three Component LocationAccessing Components in the Console Electrostatic Discharge ESD Sensitive ElectronicsRemoving the Console Removing Console ComponentsRemoving the Machine Control Board Removing the Motor Control BoardRemoving the Pressure Switches Removing the Log Valve AssemblyAccessing Components Beneath the Washer TOP Raising the Washer Top to the Service PositionRemoving Components in the Tub Ket. FigReassembling Tub Components 18bTab Accessing Components Beneath the TUB Components Accessible with Front Cabinet Panel RemovedRemoving the Front Cabinet Panel Servicing Components from the Bottom of the Washer Removing the Drive MotorRemoving the Thrust Plate Motor mounting bracket to the motor plateRemoving the Brake Assembly/Nutate Shaft 32 shows all the components of the thrust plate assemblyRemoving the Pump and Pump Motor Replacing the CapacitorReplacing the Outer Tub Troubleshooting and Diagnosis Troubleshooting ChartSection Four Overfills Won’t NutateWon’t Spin Motor OverheatsTemperature Won’t DrainWasher Vibrating Incorrect WaterPower Failure Processor ResetError Load is WrinkledLid Switch Error Long DrainAverage Current LimitSelf Diagnostic Routines Automatic Service Diagnostics ModeOpen Lid Suds LockManual Diagnostic Mode PressSOAK Cycle Signal Soak Cycle SignalRunning Nutate or Spin Pump Drain/Recirculation Nutate and Recirculate TestWater Inlet and Dispenser VALVE, Operating PS Test Console Switches and Indicators Test If none of the LEDs light upIf a particular group of LEDs does not light up If a single LED does not light upKEY Switch Matrix Checking Touchpad FunctioningSales Demo Mode Checking Drive and Pump Motor ContinuityTroubleshooting Tests 120VAC Electrical SupplyWater Inlet and Dispenser Solenoid Test Motor and Motor Control System Test Machine Control RelayMotor Controller Automatic Temperature Control Test Drive Motor and Wiring HarnessIf the fill valves are working properly Operating and Over Fill Pressure Switch Test Drain/Recirculation TestPage Page Wiring Diagram Tech TipsSection Five Component Resistance Chart Warranty InformationUnited States Rprt