Whirlpool GVW9959K-0 manual Recirculation and Drain, Water Pump/Pump Motor, Outer Tub

Page 20

RECIRCULATION AND DRAIN

Water Pump/Pump Motor

The pump is directly driven by a separate reversible 120 VAC 60 Hz motor. By being reversible, the motor provides for two separate operations of the washer.

Outer Tub

The Outer Tub sump plays a role in the drain and water recirculation function The sump area includes two check balls that direct water flow when the water pump operates in the drain and recirc direction.

Recirculation Check Ball

Drain Check Ball

Fig. 2-13

Recirculation

When water is present in the tub, the check balls will float in the proximity of the recircula- tion and drain sump ports. Water weight or water pressure applied to the ball(s) will cause them to drop away from their respective port or seal off the port.

Recirculation

Tube

Fig. 2-14

During the Recirculation Mode, the pump motor turns counter-clockwise (as viewed from underneath the washer). This causes the water pump to draw water from the tub through the drain sump port, forcing the recirculation check ball to seal the recirculation sump port and force water through the recirculation tube outlet. Water is recirculated back into the tub onto the load.

Drain Check Ball drops from weight of water in tub and negative pressure from pump

Recirculation Check Ball seals off the Recirculation port, due to positive pump pressure, forcing water to flow out of Recirculation Feed Tube

Recirculation Feed Tube

Fig. 2-15

Pump Direction

To Drain Hose

16

Image 20
Contents Page Introduction Table of Contents Model Number Designator Model Number G V W 9 9 5 9 K Q SafetyMODEL/SERIAL Number Plate Serial Number Designator Installation ConsiderationsSection ONE For a permanently connected washerTools needed Parts Supplied DrainSystem ConnectingtheDrainHose InstallationChecklist Use&CareInformation Theory of Operation Section TWONutation Control PanelSoil Level Operational Cycle Default Wash and SpinOption Descriptions Water Temp Assured Water TempATC Thresholds Whitest WhitesEnd of Cycle Signal Additional OptionsDrive Motor Machine ControllerMotor Controller Peekaboo Mode LevelerUniversal Joint Shield Capacitor Interlock SwitchesDrive System OPR FLD Pressure SwitchesLOG Valve Assembly Recirculation and Drain Water Pump/Pump MotorOuter Tub RecirculationDrain Changing Cycles and OptionsChanging Cycles after pressing Start Changing Options after pressing StartOperational Cycle Notes Drive Motor Notes Pump Drive Description Water Description Water Pump Drive Duration Description Water Pump Drive Pump Drive Description Action Speed Pump Drive Description Delicate/Casual SPIN+RECIRC+FILL Wash Detergent PS Controlled Recirc Spin Handwash Garments are labelled Hand Wash becauseExtend Spin Cycle Soak CycleExtra Rinse When to use Rinse & Spin To use or change Rinse & Spin settingsSuds Lock Detection/Cleanout Rinse & SpinComponent Access Special TOOLS/PARTS Required for ServiceSection Three Component LocationAccessing Components in the Console Electrostatic Discharge ESD Sensitive ElectronicsRemoving the Console Removing Console ComponentsRemoving the Machine Control Board Removing the Motor Control BoardRemoving the Pressure Switches Removing the Log Valve AssemblyAccessing Components Beneath the Washer TOP Raising the Washer Top to the Service PositionRemoving Components in the Tub Ket. FigReassembling Tub Components 18bTab Removing the Front Cabinet Panel Accessing Components Beneath the TUBComponents Accessible with Front Cabinet Panel Removed Servicing Components from the Bottom of the Washer Removing the Drive MotorRemoving the Thrust Plate Motor mounting bracket to the motor plateRemoving the Brake Assembly/Nutate Shaft 32 shows all the components of the thrust plate assemblyReplacing the Outer Tub Removing the Pump and Pump MotorReplacing the Capacitor Section Four Troubleshooting and DiagnosisTroubleshooting Chart Overfills Won’t NutateWon’t Spin Motor OverheatsTemperature Won’t DrainWasher Vibrating Incorrect WaterPower Failure Processor ResetError Load is WrinkledLid Switch Error Long DrainAverage Current LimitSelf Diagnostic Routines Automatic Service Diagnostics ModeOpen Lid Suds LockRunning Nutate or Spin Manual Diagnostic ModePressSOAK Cycle Signal Soak Cycle Signal Pump Drain/Recirculation Nutate and Recirculate TestWater Inlet and Dispenser VALVE, Operating PS Test Console Switches and Indicators Test If none of the LEDs light upIf a particular group of LEDs does not light up If a single LED does not light upKEY Switch Matrix Checking Touchpad FunctioningSales Demo Mode Checking Drive and Pump Motor ContinuityWater Inlet and Dispenser Solenoid Test Troubleshooting Tests120VAC Electrical Supply Motor Controller Motor and Motor Control System TestMachine Control Relay If the fill valves are working properly Automatic Temperature Control TestDrive Motor and Wiring Harness Operating and Over Fill Pressure Switch Test Drain/Recirculation TestPage Page Section Five Wiring DiagramTech Tips Component Resistance Chart Warranty InformationUnited States Rprt