Whirlpool GVW9959K-0 manual

Page 63

Remove the connector at the motor and take measurements as shown in the following table.

Recirc to Neutral

10 - 12

RD to WH

Drain to Neutral

10 - 12

YL to WH

Recirc to Drain

20 - 25

RD to YL

If the resistance is much higher than shown, replace the pump motor.

If the resistance at the pump motor is correct, there is an open circuit in the wiring between the motor and the motor controller. Repair or replace the lower wiring harness.

If the pump motor windings and motor controller are OK, repair or replace the pump.

59

Image 63
Contents Page Introduction Table of Contents Safety MODEL/SERIAL Number Plate Serial Number DesignatorModel Number Designator Model Number G V W 9 9 5 9 K Q For a permanently connected washer InstallationConsiderations Section ONETools needed Parts Supplied DrainSystem ConnectingtheDrainHose InstallationChecklist Use&CareInformation Control Panel Theory of OperationSection TWO NutationOperational Cycle Default Wash and Spin Option DescriptionsSoil Level Whitest Whites Water TempAssured Water Temp ATC ThresholdsAdditional Options End of Cycle SignalMachine Controller Motor ControllerDrive Motor Leveler Peekaboo ModeUniversal Joint Interlock Switches Drive SystemShield Capacitor Pressure Switches LOG Valve AssemblyOPR FLD Recirculation Recirculation and DrainWater Pump/Pump Motor Outer TubChanging Options after pressing Start DrainChanging Cycles and Options Changing Cycles after pressing StartOperational Cycle Notes Drive Motor Notes Pump Drive Description Water Description Water Pump Drive Duration Description Water Pump Drive Pump Drive Description Action Speed Pump Drive Description Delicate/Casual SPIN+RECIRC+FILL Wash Detergent PS Controlled Recirc Spin Garments are labelled Hand Wash because HandwashSoak Cycle Extra RinseExtend Spin Cycle Rinse & Spin When to use Rinse & SpinTo use or change Rinse & Spin settings Suds Lock Detection/CleanoutComponent Location Component AccessSpecial TOOLS/PARTS Required for Service Section ThreeElectrostatic Discharge ESD Sensitive Electronics Accessing Components in the ConsoleRemoving the Motor Control Board Removing the ConsoleRemoving Console Components Removing the Machine Control BoardRemoving the Log Valve Assembly Removing the Pressure SwitchesRaising the Washer Top to the Service Position Accessing Components Beneath the Washer TOPKet. Fig Removing Components in the Tub18b Reassembling Tub ComponentsTab Accessing Components Beneath the TUB Components Accessible with Front Cabinet Panel RemovedRemoving the Front Cabinet Panel Motor mounting bracket to the motor plate Servicing Components from the Bottom of the WasherRemoving the Drive Motor Removing the Thrust Plate32 shows all the components of the thrust plate assembly Removing the Brake Assembly/Nutate ShaftRemoving the Pump and Pump Motor Replacing the CapacitorReplacing the Outer Tub Troubleshooting and Diagnosis Troubleshooting ChartSection Four Motor Overheats OverfillsWon’t Nutate Won’t SpinIncorrect Water TemperatureWon’t Drain Washer VibratingLoad is Wrinkled Power FailureProcessor Reset ErrorLimit Lid Switch ErrorLong Drain Average CurrentSuds Lock Self Diagnostic RoutinesAutomatic Service Diagnostics Mode Open LidManual Diagnostic Mode PressSOAK Cycle Signal Soak Cycle SignalRunning Nutate or Spin Nutate and Recirculate Test Pump Drain/RecirculationWater Inlet and Dispenser VALVE, Operating PS Test If a single LED does not light up Console Switches and Indicators TestIf none of the LEDs light up If a particular group of LEDs does not light upChecking Touchpad Functioning KEY Switch MatrixChecking Drive and Pump Motor Continuity Sales Demo ModeTroubleshooting Tests 120VAC Electrical SupplyWater Inlet and Dispenser Solenoid Test Motor and Motor Control System Test Machine Control RelayMotor Controller Automatic Temperature Control Test Drive Motor and Wiring HarnessIf the fill valves are working properly Drain/Recirculation Test Operating and Over Fill Pressure Switch TestPage Page Wiring Diagram Tech TipsSection Five Warranty Information Component Resistance ChartUnited States Rprt