Whirlpool GVW9959K-0 manual Additional Options, End of Cycle Signal

Page 14

THERMISTOR RESISTANCE CHART

THERMISTOR RESISTANCE

TEMP

RESISTANCE VALUE

° F

 

 

 

 

 

40

126k

- 135k ohms

50

97k - 102k ohms

60

75k

- 78k ohms

70

58k

- 61k ohms

80

46k

- 47k ohms

90

36k

- 37k ohms

100

28k

- 30k ohms

110

23k

- 24k ohms

120

18k

- 19k ohms

130

15k

- 16k ohms

140

12k

- 13k ohms

150

10k - 11k ohms

 

 

 

Additional Options

 

DESCRIPTIONS

 

 

OPTIONS

 

 

 

Soak

Loosens soils when added to a cycle. Selection of

 

SOAK will add approximately 16 minutes to the wash

 

portion of the cycle.

Extra Rinse

Adds an additional rinse to any cycle.

Extend Spin

Adds three, (3), minutes to the final spin time of any

 

cycle.

 

 

End of Cycle Signal

There are three (3) volume levels for the End of Cycle Signal, HIGH, LOW and OFF. Pressing the END OF CYCLE SIGNAL keypad toggles between these options by lighting one of the LEDs and beeping the corresponding end of cycle signal at the volume level selected. The LED remains lit during program mode and running mode until the cycle is complete.

If OFF is selected, no end of cycle signal will beep, but all key and warning beeps are active.

The end of cycle signal is set at a short high pitched, followed by a longer lower pitched tone, repeated four times.

10

Image 14
Contents Page Introduction Table of Contents Model Number Designator Model Number G V W 9 9 5 9 K Q SafetyMODEL/SERIAL Number Plate Serial Number Designator Section ONE InstallationConsiderations For a permanently connected washerTools needed Parts Supplied DrainSystem ConnectingtheDrainHose InstallationChecklist Use&CareInformation Nutation Theory of OperationSection TWO Control PanelSoil Level Operational Cycle Default Wash and SpinOption Descriptions ATC Thresholds Water TempAssured Water Temp Whitest WhitesEnd of Cycle Signal Additional OptionsDrive Motor Machine ControllerMotor Controller Peekaboo Mode LevelerUniversal Joint Shield Capacitor Interlock SwitchesDrive System OPR FLD Pressure SwitchesLOG Valve Assembly Outer Tub Recirculation and DrainWater Pump/Pump Motor RecirculationChanging Cycles after pressing Start DrainChanging Cycles and Options Changing Options after pressing StartOperational Cycle Notes Drive Motor Notes Pump Drive Description Water Description Water Pump Drive Duration Description Water Pump Drive Pump Drive Description Action Speed Pump Drive Description Delicate/Casual SPIN+RECIRC+FILL Wash Detergent PS Controlled Recirc Spin Handwash Garments are labelled Hand Wash becauseExtend Spin Cycle Soak CycleExtra Rinse Suds Lock Detection/Cleanout When to use Rinse & SpinTo use or change Rinse & Spin settings Rinse & SpinSection Three Component AccessSpecial TOOLS/PARTS Required for Service Component LocationAccessing Components in the Console Electrostatic Discharge ESD Sensitive ElectronicsRemoving the Machine Control Board Removing the ConsoleRemoving Console Components Removing the Motor Control BoardRemoving the Pressure Switches Removing the Log Valve AssemblyAccessing Components Beneath the Washer TOP Raising the Washer Top to the Service PositionRemoving Components in the Tub Ket. FigReassembling Tub Components 18bTab Removing the Front Cabinet Panel Accessing Components Beneath the TUBComponents Accessible with Front Cabinet Panel Removed Removing the Thrust Plate Servicing Components from the Bottom of the WasherRemoving the Drive Motor Motor mounting bracket to the motor plateRemoving the Brake Assembly/Nutate Shaft 32 shows all the components of the thrust plate assemblyReplacing the Outer Tub Removing the Pump and Pump MotorReplacing the Capacitor Section Four Troubleshooting and DiagnosisTroubleshooting Chart Won’t Spin OverfillsWon’t Nutate Motor OverheatsWasher Vibrating TemperatureWon’t Drain Incorrect WaterError Power FailureProcessor Reset Load is WrinkledAverage Current Lid Switch ErrorLong Drain LimitOpen Lid Self Diagnostic RoutinesAutomatic Service Diagnostics Mode Suds LockRunning Nutate or Spin Manual Diagnostic ModePressSOAK Cycle Signal Soak Cycle Signal Pump Drain/Recirculation Nutate and Recirculate TestWater Inlet and Dispenser VALVE, Operating PS Test If a particular group of LEDs does not light up Console Switches and Indicators TestIf none of the LEDs light up If a single LED does not light upKEY Switch Matrix Checking Touchpad FunctioningSales Demo Mode Checking Drive and Pump Motor ContinuityWater Inlet and Dispenser Solenoid Test Troubleshooting Tests120VAC Electrical Supply Motor Controller Motor and Motor Control System TestMachine Control Relay If the fill valves are working properly Automatic Temperature Control TestDrive Motor and Wiring Harness Operating and Over Fill Pressure Switch Test Drain/Recirculation TestPage Page Section Five Wiring DiagramTech Tips Component Resistance Chart Warranty InformationUnited States Rprt