ADC AD-410 service manual 103

Page 107

11)Replace ALL the wires removed in Step #5 (refer to previous page [page 91]).

12)Mount the top of the thermal magnetic starter to the top of the din rail and press down and in. Inspect ALL of the work performed.

13)Set the control of the thermal magnetic starter to the "start" position.

14)Reestablish electrical power to the dryer.

7.Rotational Sensor Assembly

The Rotational Sensor Assembly is located on the right rear drive wheel. It consists of a magnetic rotational switch, mounted on the bracket which is bolted to the pillow block bearing. A magnet is riveted to the drive wheel.

The magnetic rotational sensor switch senses the rotation of the tumbler (basket). If the gap between the sensor switch and the magnet is greater than a preset amount, then the dryer will shut down on "SEFL" ("rotational sensor failure").

a)Rotational Sensor Switch Replacement

1)Discontinue electric service to the dryer.

2)Remove the adjustment nut closest to the drive wheel.

3)Remove the magnetic rotational sensor switch from the mounting bracket.

4)Depress the tabs on the rotational sensor harness plug and pull apart, then remove the sensor switch.

5)To install a new sensor switch, connect the plug of the new sensor switch to the sensor harness.

6)Place one (1) adjustment nut onto the sensor switch and insert into the mounting bracket.

7) Place the second adjustment nut on but do not tighten.

The magnet on the drive wheel and the sensor switch must be in a horizontal line to one another.

8) The gap between the magnet and the sensor switch must be 1/8-inch (5.71 cm).

9) Tighten the adjustment nuts installed in Step #7 and Step #6.

10)Reestablish electrical service to the dryer.

103

Image 107
Contents American Dryer Corporation Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Troubleshooting AD-410 Reference Guide Base Section AD-410 Machine Operational Summary AD-410 Operator CONTROLS/INDICATORSControl Power On END of Cycle / Heater Fault Indicator / AIR JET AIR JET AD-410 Machine Operation Troubleshooting InformationLoad Tilted Unload TiltedDRY GAS Pressure If Both AIR Flow Switches are not Open AT this TimeImportant Information ONE 1 Burner will not Ignite During a Drying Cycle System Ladder DiagramONE 1 Burner will not Ignite AT the Beginning of a Cycle Lint Drawer / Guard Status Optional Sprinkler Control SignalsSolenoid Control Page What to do if YOU Smell GAS Explosion could ResultNational Electric Code ANSI/NFPA no -LATEST Edition StandardsLiquids CleaningSuggested Cleaning Schedule Monthly Lubrication Days After Installation and Every 6 Months Thereafter AdjustmentsGas Dimensions AD-410 with Inlet AIR Adapter Enclosure / AIR Supply / Exhaust Requirements Installation RequirementsElectrical Requirements and GAS Requirements Operational Service Check ProcedureDirect Spart Ignition DSI System COMPONENTS/FUNCTIONS Heat Section24 VAC Direct Spark Ignition DSI Module Repairable ADC Direct Spark Ignition DSI Operation Flow Chart Manometer Troubleshooting the Direct Spark Ignition DSI SystemMAN0677 Page If not, refer to the Second Visual Check on First Visual Check Second Visual Check Third Visual Check Are no Retries Leaks with a Flame Continuously Page Page Create a Potential Safety Hazard Page General Overview Steam Coil System OperationPage Page Page Page Sprinkler System Description Require any adjustment Page Page Supplies Before Servicing the Dryer MAN3169 Tilting System Description Page Tilting Pistons Page Page Page Page AIR JET Assembly Page Blower Squirrel Cage Fan Motor Assembly Leave enough movement for V-belt adjustment Page Important do not Overtighten V-BELTS Important do not Overtighten V-BELTS Page Page Filter and Regulator Assembly Door Systems Page Page Page Page Allow a full 72 hours for the silicone to cure Page Control and Electrical System Page Button does not Disable the High Voltage to the Dryer If the Opposite Side is not LEVEL, the Dryer will not Tilt ºC + Page Page Page Page Page Page MAN3405 Page Page Page Tumbler Basket System Important do not Over Tighten Turnbuckle Install new V-belts Tighten turnbuckle For Gear Reducer removal refer to Section d on page 99 Page Do not tighten 101 102 103 Troubleshooting Drive motor is not operating does not start Impellor fan motor is not operating does not start 107 108 Dryer operates but is taking too long to dry Excessive noise and vibration Dryer will not level from a tilt position Procedure for Functional Check Replacement Components 113 ADC450414 1- 05/27/99-25