ADC AD-410 service manual Impellor fan motor is not operating does not start

Page 110

2. Failed overload protector.

E.Impellor (fan) motor is not operating (does not start)...

*Microprocessor controller (computer) “MTR” relay output indicator is on.

1.Blown blower (impellor and fan) motor fuses or overloads.

2.Failed blower (impellor and fan) motor contactor (relay).

3.Failed blower (fan and impellor) motor.

4.Sail switch verification circuit not in open position prior to the start of the drying cycle.

*Microprocessor controller (computer) “MTR” relay output indicator is off.

1.Failed microprocessor controller (computer).

F.Blower (fan and impellor) motor operates okay for a few minutes and then either repeatedly or occasionally trips the overload protector...

NOTE: When the overload protector trips, the microprocessor controller (computer) L.E.D. (light emitting diode) display will read “door.”

1.Motor is overheating ...

a.Motor air vents clogged with lint.

b.Low voltage to motor.

c.Failed motor.

d.Tumbler (basket) is binding... check for an obstruction.

e.Failed gear reducer or tumbler bearing.

f.V-belts are too tight.

h.Motor is running at incorrect voltage.

2.Failed overload protector.

G.Both drive motor and blower (fan and impellor) motor are not operating... microprocessor controller (computer) L.E.D. (light emitting diode) motor indicator dots and the “MTR” relay output and forward “FWD” or reverse “REV” L.E.D. indicators are on.

1.Blown drive motor and blower (fan and impellor) motor fuses or overloads.

2.Failed motors (both blower [fan and impellor] motor and drive motor).

106

Image 110
Contents American Dryer Corporation Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserFor Your Safety Page Table of Contents Section Troubleshooting AD-410 Reference Guide Base Section AD-410 Operator CONTROLS/INDICATORS AD-410 Machine Operational SummaryControl Power On END of Cycle / Heater Fault Indicator / AIR JET AD-410 Machine Operation Troubleshooting Information AIR JETUnload Tilted Load TiltedDRY If Both AIR Flow Switches are not Open AT this Time GAS PressureImportant Information ONE 1 Burner will not Ignite During a Drying Cycle System Ladder DiagramONE 1 Burner will not Ignite AT the Beginning of a Cycle Lint Drawer / Guard Status Optional Sprinkler Control SignalsSolenoid Control Page Explosion could Result What to do if YOU Smell GASStandards National Electric Code ANSI/NFPA no -LATEST EditionLiquids CleaningSuggested Cleaning Schedule Monthly Lubrication Adjustments Days After Installation and Every 6 Months ThereafterGas Dimensions AD-410 with Inlet AIR Adapter Installation Requirements Enclosure / AIR Supply / Exhaust RequirementsOperational Service Check Procedure Electrical Requirements and GAS RequirementsHeat Section Direct Spart Ignition DSI System COMPONENTS/FUNCTIONS24 VAC Direct Spark Ignition DSI Module Repairable ADC Direct Spark Ignition DSI Operation Flow Chart Troubleshooting the Direct Spark Ignition DSI System ManometerMAN0677 Page If not, refer to the Second Visual Check on First Visual Check Second Visual Check Third Visual Check Are no Retries Leaks with a Flame Continuously Page Page Create a Potential Safety Hazard Page Steam Coil System Operation General OverviewPage Page Page Page Sprinkler System Description Require any adjustment Page Page Supplies Before Servicing the Dryer MAN3169 Tilting System Description Page Tilting Pistons Page Page Page Page AIR JET Assembly Page Blower Squirrel Cage Fan Motor Assembly Leave enough movement for V-belt adjustment Page Important do not Overtighten V-BELTS Important do not Overtighten V-BELTS Page Page Filter and Regulator Assembly Door Systems Page Page Page Page Allow a full 72 hours for the silicone to cure Page Control and Electrical System Page Button does not Disable the High Voltage to the Dryer If the Opposite Side is not LEVEL, the Dryer will not Tilt ºC + Page Page Page Page Page Page MAN3405 Page Page Page Tumbler Basket System Important do not Over Tighten Turnbuckle Install new V-belts Tighten turnbuckle For Gear Reducer removal refer to Section d on page 99 Page Do not tighten 101 102 103 Troubleshooting Drive motor is not operating does not start Impellor fan motor is not operating does not start 107 108 Dryer operates but is taking too long to dry Excessive noise and vibration Dryer will not level from a tilt position Procedure for Functional Check Replacement Components 113 ADC450414 1- 05/27/99-25