ADC AD-410 service manual Gas

Page 26

SECTION III

SPECIFICATIONS and DIMENSIONS

A. SPECIFICATIONS (Gas and Steam Models)

MAXIMUM CAPACITY (DRY WEIGHT)

 

410 lbs.

186.4 kg

MINIMUM CAPACITY (DRY WEIGHT)

 

250 lbs.

113.65 kg

BASKET (TUMBLER) DIAMETER

 

68-3/4"

174.6 cm

BASKET (TUMBLER) DEPTH

 

66-3/8"

168.6 cm

BASKET (TUMBLER) VOLUME

 

143 cu. ft.

4.05 cu.m.

DRIVE MOTOR

 

 

7-1/2 HP

5.6 kw

BLOWER MOTOR (GAS/STEAM)

 

25 HP

18.7 kw

DOOR OPENING

 

40" WIDE x 50" HIGH

101.6 cm x 127 cm

DOOR SILL HEIGHT - LEVEL

 

39-3/4"

101 cm

COMPRESSED AIR

 

 

80 PSI

5.63 kg/cu.m.

COMPRESSED AIR CONNECTION

 

3/8" F.P.T.

.953 cm

Gas*

VOLTAGE AVAILABLE

 

208-460v / 3ø / 3, 4w / 50/60 Hz

HEAT INPUT

 

1,600,000 btu/hr

403,200 kcal/hr

AIRFLOW

 

 

9,200 cfm

261 cmm

 

APPROX. WEIGHT (UNCRATED)

 

7,500 lbs.

3,409 kg

 

 

 

 

 

 

 

 

 

Inlet Pipe Size

 

2" F.P.T.

5.08 cm

 

VOLTAGE AVAILABLE

 

208-460v / 3ø / 3, 4w / 50/60 Hz

Steam*

APPROX. WEIGHT (UNCRATED)

 

8,000 lbs.

3,636 kg

1,815 lbs/hr

825 kg/hr

 

55

340 cmm

 

AIRFLOW

 

 

12,000 cfm

 

STEAM COMSUMPTION

 

BOILER HP

 

 

 

NORMAL LOAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATING STEAM PRESSURE

STEAM SUPPLY

STEAM RETURN

 

125 psi max

8.79 kg/sq cm

2"

 

5.08 cm

1-1/4"

3.18 cm

Shaded areas are stated in metric equivalents.

*Dryer must be provided with a clean, dry, regulated 80 PSI (+/- 10 psi) air supply (equivalent volume - 11 cfh [0.3 cmh]).

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation.

2 2

Image 26
Contents American Dryer Corporation Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserFor Your Safety Page Table of Contents Section Troubleshooting AD-410 Reference Guide Base Section AD-410 Operator CONTROLS/INDICATORS AD-410 Machine Operational SummaryControl Power On END of Cycle / Heater Fault Indicator / AIR JET AD-410 Machine Operation Troubleshooting Information AIR JETUnload Tilted Load TiltedDRY If Both AIR Flow Switches are not Open AT this Time GAS PressureImportant Information ONE 1 Burner will not Ignite During a Drying Cycle System Ladder DiagramONE 1 Burner will not Ignite AT the Beginning of a Cycle Lint Drawer / Guard Status Optional Sprinkler Control SignalsSolenoid Control Page Explosion could Result What to do if YOU Smell GASStandards National Electric Code ANSI/NFPA no -LATEST EditionLiquids CleaningSuggested Cleaning Schedule Monthly Lubrication Adjustments Days After Installation and Every 6 Months ThereafterGas Dimensions AD-410 with Inlet AIR Adapter Installation Requirements Enclosure / AIR Supply / Exhaust RequirementsOperational Service Check Procedure Electrical Requirements and GAS RequirementsHeat Section Direct Spart Ignition DSI System COMPONENTS/FUNCTIONS24 VAC Direct Spark Ignition DSI Module Repairable ADC Direct Spark Ignition DSI Operation Flow Chart Troubleshooting the Direct Spark Ignition DSI System ManometerMAN0677 Page If not, refer to the Second Visual Check on First Visual Check Second Visual Check Third Visual Check Are no Retries Leaks with a Flame Continuously Page Page Create a Potential Safety Hazard Page Steam Coil System Operation General OverviewPage Page Page Page Sprinkler System Description Require any adjustment Page Page Supplies Before Servicing the Dryer MAN3169 Tilting System Description Page Tilting Pistons Page Page Page Page AIR JET Assembly Page Blower Squirrel Cage Fan Motor Assembly Leave enough movement for V-belt adjustment Page Important do not Overtighten V-BELTS Important do not Overtighten V-BELTS Page Page Filter and Regulator Assembly Door Systems Page Page Page Page Allow a full 72 hours for the silicone to cure Page Control and Electrical System Page Button does not Disable the High Voltage to the Dryer If the Opposite Side is not LEVEL, the Dryer will not Tilt ºC + Page Page Page Page Page Page MAN3405 Page Page Page Tumbler Basket System Important do not Over Tighten Turnbuckle Install new V-belts Tighten turnbuckle For Gear Reducer removal refer to Section d on page 99 Page Do not tighten 101 102 103 Troubleshooting Drive motor is not operating does not start Impellor fan motor is not operating does not start 107 108 Dryer operates but is taking too long to dry Excessive noise and vibration Dryer will not level from a tilt position Procedure for Functional Check Replacement Components 113 ADC450414 1- 05/27/99-25