ADC AD-410 service manual Require any adjustment

Page 55

d) Sprinkler Digital Temperature Controller

The sprinkler digital temperature controller is a programmable

MAN3488

 

microprocessor used to monitor temperatures via a Resistive

 

Temperature Device (RTD).

 

 

 

NOTE: Operating parameters are preset at the factory and should not

 

require any adjustment.

 

 

 

2. Sprinkler System Operation

NOTE: Refer to the ladder diagram provided with the dryer for specific relay logic.

Master Relay -The coil in this relay must be energized in order to close the contacts needed to supply power to the dryers control system.

Relay 1 - The coil in this relay energizes if the set- point is reached closing Contact 1 and Contact 2. Contact 1 latches Relay 1 on. Contact 2 closes, turning on the sprinkler, the horn, and the reset button light. Relay 1 will remain energized until the reset button is pushed.

Relay 2 - The coil in this relay energizes if the set- point is reached closing Contact 3, de- energizing the Master Relay, and shutting power off to the dryer. Relay 2 will remain energized until the reset button is pushed.

NOTE: The Sprinkler System will remain on until the tumbler (basket) temperature falls below the set-point, and the reset button is manually activated.

5 1

Image 55
Contents American Dryer Corporation Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Troubleshooting AD-410 Reference Guide Base Section AD-410 Machine Operational Summary AD-410 Operator CONTROLS/INDICATORSControl Power On END of Cycle / Heater Fault Indicator / AIR JET AIR JET AD-410 Machine Operation Troubleshooting InformationLoad Tilted Unload TiltedDRY GAS Pressure If Both AIR Flow Switches are not Open AT this TimeImportant Information ONE 1 Burner will not Ignite AT the Beginning of a Cycle System Ladder DiagramONE 1 Burner will not Ignite During a Drying Cycle Solenoid Control Optional Sprinkler Control SignalsLint Drawer / Guard Status Page What to do if YOU Smell GAS Explosion could ResultNational Electric Code ANSI/NFPA no -LATEST Edition StandardsSuggested Cleaning Schedule CleaningLiquids Monthly Lubrication Days After Installation and Every 6 Months Thereafter AdjustmentsGas Dimensions AD-410 with Inlet AIR Adapter Enclosure / AIR Supply / Exhaust Requirements Installation RequirementsElectrical Requirements and GAS Requirements Operational Service Check ProcedureDirect Spart Ignition DSI System COMPONENTS/FUNCTIONS Heat Section24 VAC Direct Spark Ignition DSI Module Repairable ADC Direct Spark Ignition DSI Operation Flow Chart Manometer Troubleshooting the Direct Spark Ignition DSI SystemMAN0677 Page If not, refer to the Second Visual Check on First Visual Check Second Visual Check Third Visual Check Are no Retries Leaks with a Flame Continuously Page Page Create a Potential Safety Hazard Page General Overview Steam Coil System OperationPage Page Page Page Sprinkler System Description Require any adjustment Page Page Supplies Before Servicing the Dryer MAN3169 Tilting System Description Page Tilting Pistons Page Page Page Page AIR JET Assembly Page Blower Squirrel Cage Fan Motor Assembly Leave enough movement for V-belt adjustment Page Important do not Overtighten V-BELTS Important do not Overtighten V-BELTS Page Page Filter and Regulator Assembly Door Systems Page Page Page Page Allow a full 72 hours for the silicone to cure Page Control and Electrical System Page Button does not Disable the High Voltage to the Dryer If the Opposite Side is not LEVEL, the Dryer will not Tilt ºC + Page Page Page Page Page Page MAN3405 Page Page Page Tumbler Basket System Important do not Over Tighten Turnbuckle Install new V-belts Tighten turnbuckle For Gear Reducer removal refer to Section d on page 99 Page Do not tighten 101 102 103 Troubleshooting Drive motor is not operating does not start Impellor fan motor is not operating does not start 107 108 Dryer operates but is taking too long to dry Excessive noise and vibration Dryer will not level from a tilt position Procedure for Functional Check Replacement Components 113 ADC450414 1- 05/27/99-25