2.Check to see that the Air Jet L.E.D. (light emitting diode) is on at the end of the drying cycle. If the L.E.D. is not on it may be an indication of a failed Phase 5 Microprocessor Controller (computer).

3.If Air Jet L.E.D. is on then check the wiring from the Phase 5 Microprocessor Controller (computer) to the air valve.

4.Bad air valve.

LOAD / DRY / UNLOAD (Selector Switch) and TILT FUNCTION (Off - On Selector Switch)

As mentioned in the machine summary (refer to page 5), the “LOAD / DRY / UNLOAD” selector switch and “TILT Off - On” selector switch work in conjunction with each other.

UNLOAD or LOAD LEVEL...opens the Vertical Doors ONLY

If this selection does not operate;

1.Check that 80 PSI of compressed air is supplied to the machine and that the door solenoid is being actuated. The “Door Open” signal is generated by the PLC (Programmable Logic Controller). Refer to the PLC information included in the ladder diagrams and schematics supplied with the machine.

UNLOAD TILTED

This selection causes the front horizontal doors to open. Once the “Door Open” signal is sensed, the PLC enables the “Rear Up” solenoid to tilt the machine. Once the tumbler section releases the tilt switch, the “JOG” functions become enabled for an operator’s selection.

If the tumbler section does not tilt forward;

1.Verify that a “Door Open” signal is being sensed by the PLC (Programmable Logic Controller).

2.Check that 80 PSI of compressed air is supplied to the machine and that the “Rear Up” solenoid is being actuated by the PLC (Programmable Logic Controller).

Refer to the PLC (Programmable Logic Controller) signal information included in the ladder diagrams and schematics supplied with the machine.

LOAD TILTED

This selection causes the front horizontal doors to open. Once the “Door Open” signal is sensed, the PLC (Programmable Logic Controller). enables the “Front Up” solenoid to tilt the machine. The “JOG” functions then becomes enabled for an operator’s selection.

If the tumbler section does not tilt towards the rear;

1. Verify that a “Door Open” signal is being sensed by the PLC (Programmable Logic Controller).

9

Image 13
Contents American Dryer Corporation Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Troubleshooting AD-410 Reference Guide Base Section AD-410 Machine Operational Summary AD-410 Operator CONTROLS/INDICATORSControl Power On END of Cycle / Heater Fault Indicator / AIR JET AIR JET AD-410 Machine Operation Troubleshooting InformationLoad Tilted Unload TiltedDRY GAS Pressure If Both AIR Flow Switches are not Open AT this TimeImportant Information ONE 1 Burner will not Ignite AT the Beginning of a Cycle System Ladder DiagramONE 1 Burner will not Ignite During a Drying Cycle Solenoid Control Optional Sprinkler Control SignalsLint Drawer / Guard Status Page What to do if YOU Smell GAS Explosion could ResultNational Electric Code ANSI/NFPA no -LATEST Edition StandardsSuggested Cleaning Schedule CleaningLiquids Monthly Lubrication Days After Installation and Every 6 Months Thereafter AdjustmentsGas Dimensions AD-410 with Inlet AIR Adapter Enclosure / AIR Supply / Exhaust Requirements Installation RequirementsElectrical Requirements and GAS Requirements Operational Service Check ProcedureDirect Spart Ignition DSI System COMPONENTS/FUNCTIONS Heat Section24 VAC Direct Spark Ignition DSI Module Repairable ADC Direct Spark Ignition DSI Operation Flow Chart Manometer Troubleshooting the Direct Spark Ignition DSI SystemMAN0677 Page If not, refer to the Second Visual Check on First Visual Check Second Visual Check Third Visual Check Are no Retries Leaks with a Flame Continuously Page Page Create a Potential Safety Hazard Page General Overview Steam Coil System OperationPage Page Page Page Sprinkler System Description Require any adjustment Page Page Supplies Before Servicing the Dryer MAN3169 Tilting System Description Page Tilting Pistons Page Page Page Page AIR JET Assembly Page Blower Squirrel Cage Fan Motor Assembly Leave enough movement for V-belt adjustment Page Important do not Overtighten V-BELTS Important do not Overtighten V-BELTS Page Page Filter and Regulator Assembly Door Systems Page Page Page Page Allow a full 72 hours for the silicone to cure Page Control and Electrical System Page Button does not Disable the High Voltage to the Dryer If the Opposite Side is not LEVEL, the Dryer will not Tilt ºC + Page Page Page Page Page Page MAN3405 Page Page Page Tumbler Basket System Important do not Over Tighten Turnbuckle Install new V-belts Tighten turnbuckle For Gear Reducer removal refer to Section d on page 99 Page Do not tighten 101 102 103 Troubleshooting Drive motor is not operating does not start Impellor fan motor is not operating does not start 107 108 Dryer operates but is taking too long to dry Excessive noise and vibration Dryer will not level from a tilt position Procedure for Functional Check Replacement Components 113 ADC450414 1- 05/27/99-25