In the State of Massachusetts, the following installation instructions apply:

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of Massachusetts.

If using a ball valve, it shall be a T-handle type.

A flexible gas connector, when used, must not exceed 3 feet.

IMPORTANT SAFETY INSTRUCTIONS

WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions, including the following:

Read all instructions before using the dryer.

Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.

Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry- cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.

Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.

Before the dryer is removed from service or discarded, remove the door to the drying compartment.

Do not reach into the dryer if the drum is moving.

Do not install or store the dryer where it will be exposed to the weather.

Do not tamper with controls.

Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.

Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.

Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.

Clean lint screen before or after each load.

Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.

The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.

See installation instructions for grounding requirements.

SAVE THESE INSTRUCTIONS

IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.

The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.

4

Image 4
Contents Sécheuse À GAZ W10151609ATable of Contents Table DES MatièresDryer Safety Your safety and the safety of others are very importantImportant Safety Instructions Tools and Parts Installation InstructionsLocation Requirements Mobile Home Additional Installation Requirements Dryer DimensionsMobile home installations require Electrical Requirements Gas Supply RequirementsGas Type Gas Supply LineGas supply pressure testing Venting RequirementsGas supply connection requirements Burner Input RequirementsIf using an existing vent system If this is a new vent system Vent materialPlan Vent System Special provisions for mobile home installationsDetermine vent path Install Vent System Install Leveling LegsVent system chart Make Gas ConnectionConnect Vent Level DryerReverse Door Swing Optional Complete Installation If the dryer will not start, check the followingDryer USE Starting Your DryerCleaning the Dryer Location Cleaning the Lint ScreenEvery Load Cleaning Drying Rack OptionCleaning the Dryer Interior Removing Accumulated LintVacation and Moving Care Changing the Drum LightDryer Operation TroubleshootingDryer Results Cycle time too short Lint on loadStains on load or drum Loads are wrinkledAssistance or Service AccessoriesU.S.A CanadaMaytag Corporation Major Appliance Warranty ONE Year Limited WarrantySécurité DE LA Sécheuse Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Exigences d’installation Instructions D’INSTALLATIONOutillage et pièces nécessaires Dimensions de la sécheuse Espacements d’installation’installation dans une maison mobile exige Type de gaz Spécifications électriquesGaz naturel Caractéristiques d’alimentation du brûleur Canalisation d’arrivée de gaz de la sécheuseAltitudes supérieures à 10 000 pi 3048 m Épreuve sous pression de l’alimentation en gazExigences concernant lévacuation En cas dutilisation du système dévacuation existantPlanification du système d’évacuation ÉvacuationAutres installations où le dégagement est réduit Déterminer litinéraire dacheminement du conduitInstallation du système d’évacuation Installation des pieds de nivellementRaccordement au gaz Pour utilisation dans une maison mobileRaccordement du conduit d’évacuation Mise à niveau de la sécheuseAchever l’installation Si la sécheuse ne démarre pas, vérifier ce qui suitUtilisation DE LA Sécheuse Mise en marche de la sécheuseEntretien DE LA Sécheuse Nettoyage de lemplacement de la sécheuseOption grille de séchage Nettoyage du filtre à charpie Nettoyage de l’intérieur de la sécheuseComment enlever la charpie accumulée DéménagementChangement de l’ampoule du tambour DépannageFonctionnement de la sécheuse La minuterie ne progresse pas visiblement Résultats de la sécheuseTemps de programme trop court Accessoires Assistance OU ServiceAu Canada Garantie DES Gros Appareils Ménagers Maytag Corporation W10151609A SP PN W10151610A Tous droits réservés