Maytag W10151609A manual Dryer Dimensions, Mobile Home Additional Installation Requirements

Page 6

Dryer Dimensions

Companion appliance spacing should also be considered.

22³⁄₄"

(57.8 cm)

43³⁄₈" (110 cm)

18"* (45.7 cm)

1"

 

29"

(2.5 cm)

(73.66 cm)

 

 

14" max.*

48 in. 2

*

 

 

(35.6cm)

 

 

 

 

(310 cm2 )

 

 

 

 

24 in.2

*

 

 

 

 

(155 cm2 )

1"

1"*

27¾"

5"*

 

 

(2.5 cm) (2.5 cm) (70.5 cm) (12.7 cm)

3"* (7.6 cm)

3"* (7.6 cm)

*27³⁄₄"

(70.5 cm)

29"

(73.66 cm)

*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

ABC

A. Recessed area

B. Side view - closet or confined area

C. Closet door with vents

*Required spacing

Mobile Home - Additional Installation Requirements

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or the Canadian Manufactured Home Standard, CAN/CSA-Z240 MH.

Mobile home installations require:

Metal exhaust system hardware, which is available for purchase from your dealer.

Mobile Home Installation Kit Part Number 346764. See “Tools and Parts” section for information on ordering.

Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

6

Image 6
Contents Sécheuse À GAZ W10151609ATable of Contents Table DES MatièresDryer Safety Your safety and the safety of others are very importantImportant Safety Instructions Installation Instructions Tools and PartsLocation Requirements Dryer Dimensions Mobile Home Additional Installation RequirementsMobile home installations require Gas Type Electrical RequirementsGas Supply Requirements Gas Supply LineGas supply connection requirements Gas supply pressure testingVenting Requirements Burner Input RequirementsIf using an existing vent system If this is a new vent system Vent materialSpecial provisions for mobile home installations Plan Vent SystemDetermine vent path Vent system chart Install Vent SystemInstall Leveling Legs Make Gas ConnectionLevel Dryer Connect VentReverse Door Swing Optional Complete Installation If the dryer will not start, check the followingDryer USE Starting Your DryerEvery Load Cleaning Cleaning the Dryer LocationCleaning the Lint Screen Drying Rack OptionVacation and Moving Care Cleaning the Dryer InteriorRemoving Accumulated Lint Changing the Drum LightTroubleshooting Dryer OperationDryer Results Stains on load or drum Cycle time too shortLint on load Loads are wrinkledU.S.A Assistance or ServiceAccessories CanadaMaytag Corporation Major Appliance Warranty ONE Year Limited WarrantySécurité DE LA Sécheuse Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Instructions D’INSTALLATION Exigences d’installationOutillage et pièces nécessaires Espacements d’installation Dimensions de la sécheuse’installation dans une maison mobile exige Spécifications électriques Type de gazGaz naturel Altitudes supérieures à 10 000 pi 3048 m Caractéristiques d’alimentation du brûleurCanalisation d’arrivée de gaz de la sécheuse Épreuve sous pression de l’alimentation en gazExigences concernant lévacuation En cas dutilisation du système dévacuation existantPlanification du système d’évacuation ÉvacuationAutres installations où le dégagement est réduit Déterminer litinéraire dacheminement du conduitRaccordement au gaz Installation du système d’évacuationInstallation des pieds de nivellement Pour utilisation dans une maison mobileRaccordement du conduit d’évacuation Mise à niveau de la sécheuseAchever l’installation Si la sécheuse ne démarre pas, vérifier ce qui suitUtilisation DE LA Sécheuse Mise en marche de la sécheuseNettoyage de lemplacement de la sécheuse Entretien DE LA SécheuseOption grille de séchage Comment enlever la charpie accumulée Nettoyage du filtre à charpieNettoyage de l’intérieur de la sécheuse DéménagementDépannage Changement de l’ampoule du tambourFonctionnement de la sécheuse Résultats de la sécheuse La minuterie ne progresse pas visiblementTemps de programme trop court Assistance OU Service AccessoiresAu Canada Garantie DES Gros Appareils Ménagers Maytag Corporation W10151609A SP PN W10151610A Tous droits réservés