GE RPT 301 Power supply, Pressure measurement, Data Communications, Pressure connection

Page 10
Power Control
(Remote Start-Up)

2

RPT 301 User Manual

Power supply

 

Electrical Safety:

EN61010 (IEC 1010) as applicable

Voltage

4.5 to 32 V DC

Power

0.6 Watts at 5 V to 0.75 Watts at 32 V

Electromagnetic compatibility

 

............................................................

EN50081-1 (emissions)

.............................................................

EN50082-2 (immunity)

Switch on

 

Settling Time: ... Less than 5 seconds (with filtering disabled)

Pressure measurement

 

Measurement cycle:

Fixed, nominally 0.5 seconds

Reading Filter:

Single pole low pass filter, variable time constant and step response

Reading Resolution:

Programmable number of decimal places

Data Communications:

Serial RS232 or RS485 (selectable)

Software or hardware handshaking on RS232 software handshaking only on RS485.

A floating ‘volt free’ two-wire control input is provided to enable the instrument to be remotely switched on

or off.

 

Pressure connection

 

..............................................................................

G1/8 female

overpressure

1.25 x calibrated full-scale

pressure containment

5 bar a

Pressure medium compatibility:

 

Dry gases compatible with:

 

Glass, Silicon, Titanium, Stainless Steel and Epoxy adhesive

Note: Continuing development sometimes necessitates specification changes without notice.

K177 Issue No. 3

Image 10
Contents RPT General Electric Company. All rights reserved RPT Digital Output Pressure Transducer K177 K177 Issue No Safety Abbreviations and Symbols Iii K177 Issue No Description SpecificationDimensions AccuracyData Communications Power supplyPressure measurement Pressure connectionAccessories Mounting the Instrument Figure Pressure ConnectionInstrument Dimensions Electrical Connection Communication connectionsConnections for remote on/off control Communications Changing the communication interface standard FigureLK1 LK2 PL3PL1 RPT ScreeningCommand Summary System OperationSet-up Command Function MeasurementCR Crlf Command Terminators User calibrationSingle commands General Command FormatCommand Strings Page Error Message General Reply FormatData out of range Get reading Detailed Command Definitions Measurement CommandsReturn stored reading Auto send readingAuto Send from switch-on Set-up Commands Unit Set-upSet Resolution Command F, step, averageFilter Set-up Set Communications Options Status Command I,S/PIN, Name ValueCR formatIdentity  Calibration Check User Calibration Linearity/Drift CompensationPIN Change PIN PIN, New PINDiagnostic Mode LED IndicatorDiagnostic Mode GeneralCleaning Approved Service Agents