Schneider Electric E4800 manual PowerLogic EM4805 internal view

Page 11

930-110-01-B.00

PowerLogicTM EM4800 Series

04/2011

Introduction

 

 

Figure 3: PowerLogic EM4805 internal view

6

7

8

9

10

1

5

4

3

2

1

Legend:

1 Cover screw location

2Meter point input (JM8)

3 Meter point input (JM1)

4 Mounting keyhole

5 Ingress punch-outs

6 Earth stud

7 Sense voltage terminal block

8 Control voltage terminal block

9 Fuse

10 Control voltage jumper

11 Modem port

12 Display

13 Remote display connector

14 Serial RS232

15 Ethernet port

16 Pulse in terminal blocks

17 Pulse out connector

11

1

12 13

14

15

16

17

1

© 201 Schneider Electric All Rights Reserved

5

Image 11
Contents PowerLogicTM Series EM4800 Digital apparatus complies with Canadian ICES-003 ProcedureIndustry Canada Class B Emission Compliance Statement  Schneider Electric All Rights Reserved Table of Contents Page Introduction PowerLogic EM4800 series System Specifications Environmental PowerLogic EM4800 series meter specificationsEM4800 Front Panel DisplayPowerLogic EM4833 and PowerLogic EM4880 internal view PowerLogic EM4805 internal view Electrical Standards Compliance Safety PrecautionsInjury Receiving InstallationPre-Installation Checklist Site Planning Access to Power and LightingMounting the PowerLogic EM4800 meter 10.2 cm 04/2011 Installation Shorting block detail 930-110-01-B.00 Inside equipment Power is offWiring diagrams Electrical personnelFor a single-phase panel with the 120V variant of the meter 201 Schneider Electric All Rights Reserved 930-110-01-B.00 201 Schneider Electric All Rights Reserved 930-110-01-B.00 Phase B CT is optional Delta service meteringInstalling the Current Transformers Source Installing 5A Converters and CTs on the PowerLogic EM4880 Shows a 5A CT connected to the converter PowerLogic EM4880 5A CT connection to converter X1 CT X2 CT Connect the two wiring harnesses to the PowerLogic EM4805 Installing the 5A CTs on the PowerLogic EM4805Remove the shorting block jumper Repeat steps 5 to 7 for remaining CTsPowerLogic EM4805 CT color pair identification Manually Testing Communications Connecting the CommunicationsConnecting the Phone Line Connecting the Ethernet CableDisplay Navigation Normal ModeDiagnostics Mode Pulse InputsRecording the Meter Map Remote DisplayInstallation Record sample shown Maintenance Regulatory Compliance Graphical symbols that appear on equipment Graphical symbolsShows the graphical symbols that appear on the equipment Index PowerLogicTM EM4800 Series 930-110-01-B.00 Index 04/2011 User Notes Page 930-110-01-B.00 04/2011
Related manuals
Manual 30 pages 57.56 Kb