PowerLogicTM EM4800 Series

930-110-01-B.00

Introduction

04/2011

 

 

Table 1: PowerLogic EM4800 series meter specifications

Specification

PowerLogic EM4833 meter

PowerLogic EM4880 meter

PowerLogic EM4805 meter

 

 

 

 

Dimensions

Height: 13.125 in. (33.5 cm)

Height: 13.125 in. (33.5 cm)

Height: 13.125 in. (33.5 cm)

 

Width: 12 in. (30.5 cm)

Width: 12 in. (30.5 cm)

Width: 17 in. (44 cm)

 

Depth: 2.125 in. (5.5 cm)

Depth: 2.125 in. (5.5 cm)

Depth: 2.125 in. (5.5 cm)

 

 

 

 

Weight

8.77 lb (3.98 kg)

8.77 lb (3.98 kg)

11.9 lb (5.4 kg)

 

 

 

 

Sense voltage

100V to 300V 50/60Hz

100V to 300V 50/60Hz

100V to 300V 50/60Hz

 

2W+N+Protective Earth Wye

2W+N+Protective Earth Wye

2W+N+Protective Earth Wye

 

3W+N+Protective Earth Wye

3W+N+Protective Earth Wye

3W+N+Protective Earth Wye

 

3W+Protective Earth Delta

3W+Protective Earth Delta

3W+Protective Earth Delta

 

 

 

 

Control voltage and current

North America: 120V 125 mA 60 Hz

North America: 120V 125 mA 60 Hz

North America: 120V 125 mA 60 Hz

 

International: 230-240V 63 mA

International: 230-240V 63 mA

International: 230-240V 63 mA

 

50/60 Hz

50/60 Hz

50/60 Hz

 

 

 

 

Current transformers

0.333 V secondary CT

80 mA secondary CT

5 A secondary CT

Measurement Category III

Note: All CTs used with the product

200 A primary CT

Note: All CTs used with the product

 

must be UL recognized/listed.

Meter burden: 4.04 ohms

must be UL recognized/listed.

 

 

 

 

 

CT burden: 20 ohms

 

 

 

Part number: METSECT80200

 

 

 

Note: All CTs used with the product

 

 

 

must be UL recognized/listed.

 

 

 

 

 

Measurement accuracy

ANSI C12.20 Class 0.5

ANSI C12.20 Class 0.5

ANSI C12.20 Class 0.5

(Accuracy compliant when

IEC 62053-22 Class 0.5S

IEC 62053-22 Class 0.5S

IEC 62053-22 Class 0.5S

used with 0.3% CTs)

 

Measurement Canada Approved

Measurement Canada Approved

 

 

EG07 compliant

EG07 compliant

 

 

 

 

Pulse inputs 1 and 2

Dry form A and solid-state form A

Dry form A and solid-state form A

Dry form A and solid-state form A

 

compatible

compatible

compatible

 

Maximum frequency 10 Hz

Maximum frequency 10 Hz

Maximum frequency 10 Hz

 

Minimum pulse width 20 ms

Minimum pulse width 20 ms

Minimum pulse width 20 ms

 

 

 

 

Non-volatile memory storage

120 days in 15-minute intervals

120 days in 15-minute intervals

120 days in 15-minute intervals

 

 

 

 

Onboard modem

V.90

V.90

V.90

 

 

 

 

Onboard Ethernet port

10/100 Mb/s

10/100 Mb/s

10/100 Mb/s

 

 

 

 

Serial port

115 kb/s

115 kb/s

115 kb/s

 

 

 

 

Fuse rating (F1)

North America:120V: T125 mA, 250V

North America:120V: T125 mA, 250V

North America:120V: T125 mA, 250V

 

International 230V: T63 mA, 250V

International 230V: T63 mA, 250V

International 230V: T63 mA, 250V

 

 

 

 

Environmental

 

 

 

 

 

 

 

Operating temperature

-40 to 70oC

-40 to 70oC

-40 to 70oC

Operating humidity

5% to 90% non-condensing

5% to 90% non-condensing

5% to 90% non-condensing

 

 

 

 

Usage environment

Indoor or enclosed outdoor

Indoor or enclosed outdoor

Indoor or enclosed outdoor

 

environment

environment

environment

 

 

 

 

Maximum altitude

9843 ft (3000 m)

9843 ft (3000 m)

9843 ft (3000 m)

 

 

 

 

Pollution degree

2

2

2

 

 

 

 

2

© 201 Schneider Electric All Rights Reserved

Image 8
Contents PowerLogicTM Series EM4800 Procedure Digital apparatus complies with Canadian ICES-003Industry Canada Class B Emission Compliance Statement  Schneider Electric All Rights Reserved Table of Contents Page PowerLogic EM4800 series System Specifications IntroductionPowerLogic EM4800 series meter specifications EnvironmentalFront Panel Display EM4800PowerLogic EM4833 and PowerLogic EM4880 internal view PowerLogic EM4805 internal view Electrical Standards Compliance Safety PrecautionsInjury Receiving InstallationPre-Installation Checklist Access to Power and Lighting Site PlanningMounting the PowerLogic EM4800 meter 10.2 cm 04/2011 Installation Shorting block detail 930-110-01-B.00 Power is off Wiring diagramsElectrical personnel Inside equipmentFor a single-phase panel with the 120V variant of the meter 201 Schneider Electric All Rights Reserved 930-110-01-B.00 201 Schneider Electric All Rights Reserved 930-110-01-B.00 Delta service metering Phase B CT is optionalInstalling the Current Transformers Source Installing 5A Converters and CTs on the PowerLogic EM4880 Shows a 5A CT connected to the converter PowerLogic EM4880 5A CT connection to converter X1 CT X2 CT Installing the 5A CTs on the PowerLogic EM4805 Connect the two wiring harnesses to the PowerLogic EM4805Repeat steps 5 to 7 for remaining CTs Remove the shorting block jumperPowerLogic EM4805 CT color pair identification Connecting the Communications Connecting the Phone LineConnecting the Ethernet Cable Manually Testing CommunicationsNormal Mode Diagnostics ModePulse Inputs Display NavigationRemote Display Recording the Meter MapInstallation Record sample shown Maintenance Regulatory Compliance Graphical symbols that appear on equipment Graphical symbolsShows the graphical symbols that appear on the equipment Index PowerLogicTM EM4800 Series 930-110-01-B.00 Index 04/2011 User Notes Page 930-110-01-B.00 04/2011