Schneider Electric E4800 manual X1 CT X2 CT

Page 32

PowerLogicTM EM4800 Series

930-110-01-B.00

Installation

04/2011

 

 

Table 2: PowerLogic EM4833 and PowerLogic EM4880 CT color pair identification

1-phase, 24 meter points

 

Network- or 1-phase, 12 meter points

3-phase, 8 meter points

 

 

 

 

 

 

 

 

 

 

Meter point ID

Connect

Connect

Meter point ID

Connect

Connect

Meter point ID

Connect

Connect

(meter point #-

X1 CT

X2 CT

(meter point #-

X1 CT

X2 CT

(meter point #-

X1 CT

X2 CT

probe #)

lead to:

lead to:

probe #)

lead to:

lead to:

probe #)

lead to:

lead to:

1-1

Black

Green

1-1

Black

Green

1-1

Black

Green

 

 

 

 

 

 

 

 

 

2-1

Black

White

1-2

Black

White

1-2

Black

White

 

 

 

 

 

 

 

 

 

3-1

Black

Red

2-1

Black

Red

1-3

Black

Red

 

 

 

 

 

 

 

 

 

4-1

Red

Green

2-2

Red

Green

2-1

Red

Green

 

 

 

 

 

 

 

 

 

5-1

Red

White

3-1

Red

White

2-2

Red

White

 

 

 

 

 

 

 

 

 

6-1

Black

Orange

3-2

Black

Orange

2-3

Black

Orange

 

 

 

 

 

 

 

 

 

7-1

Black

Brown

4-1

Black

Brown

3-1

Black

Brown

 

 

 

 

 

 

 

 

 

8-1

Black

Yellow

4-2

Black

Yellow

3-2

Black

Yellow

 

 

 

 

 

 

 

 

 

9-1

Black

Blue

5-1

Black

Blue

3-3

Black

Blue

 

 

 

 

 

 

 

 

 

10-1

Green

Yellow

5-2

Green

Yellow

4-1

Green

Yellow

 

 

 

 

 

 

 

 

 

11-1

Green

Blue

6-1

Green

Blue

4-2

Green

Blue

 

 

 

 

 

 

 

 

 

12-1

Green

White

6-2

Green

White

4-3

Green

White

 

 

 

 

 

 

 

 

 

13-1

Blue

White

7-1

Blue

White

5-1

Blue

White

 

 

 

 

 

 

 

 

 

14-1

Green

Orange

7-2

Green

Orange

5-2

Green

Orange

 

 

 

 

 

 

 

 

 

15-1

Green

Brown

8-1

Green

Brown

5-3

Green

Brown

 

 

 

 

 

 

 

 

 

16-1

Blue

Yellow

8-2

Blue

Yellow

6-1

Blue

Yellow

 

 

 

 

 

 

 

 

 

17-1

Brown

White

9-1

Brown

White

6-2

Brown

White

 

 

 

 

 

 

 

 

 

18-1

Orange

White

9-2

Orange

White

6-3

Orange

White

 

 

 

 

 

 

 

 

 

19-1

Red

Orange

10-1

Red

Orange

7-1

Red

Orange

 

 

 

 

 

 

 

 

 

20-1

Red

Yellow

10-2

Red

Yellow

7-2

Red

Yellow

 

 

 

 

 

 

 

 

 

21-1

Red

Brown

11-1

Red

Brown

7-3

Red

Brown

 

 

 

 

 

 

 

 

 

22-1

Blue

Orange

11-2

Blue

Orange

8-1

Blue

Orange

 

 

 

 

 

 

 

 

 

23-1

Yellow

White

12-1

Yellow

White

8-2

Yellow

White

 

 

 

 

 

 

 

 

 

24-1

Blue

Brown

12-2

Blue

Brown

8-3

Blue

Brown

 

 

 

 

 

 

 

 

 

26

© 201 Schneider Electric All Rights Reserved

Image 32
Contents PowerLogicTM Series EM4800 Procedure Digital apparatus complies with Canadian ICES-003Industry Canada Class B Emission Compliance Statement  Schneider Electric All Rights Reserved Table of Contents Page PowerLogic EM4800 series System Specifications IntroductionPowerLogic EM4800 series meter specifications EnvironmentalFront Panel Display EM4800PowerLogic EM4833 and PowerLogic EM4880 internal view PowerLogic EM4805 internal view Electrical Standards Compliance Safety PrecautionsInjury Receiving InstallationPre-Installation Checklist Access to Power and Lighting Site PlanningMounting the PowerLogic EM4800 meter 10.2 cm 04/2011 Installation Shorting block detail 930-110-01-B.00 Power is off Wiring diagramsElectrical personnel Inside equipmentFor a single-phase panel with the 120V variant of the meter 201 Schneider Electric All Rights Reserved 930-110-01-B.00 201 Schneider Electric All Rights Reserved 930-110-01-B.00 Delta service metering Phase B CT is optionalInstalling the Current Transformers Source Installing 5A Converters and CTs on the PowerLogic EM4880 Shows a 5A CT connected to the converter PowerLogic EM4880 5A CT connection to converter X1 CT X2 CT Installing the 5A CTs on the PowerLogic EM4805 Connect the two wiring harnesses to the PowerLogic EM4805Repeat steps 5 to 7 for remaining CTs Remove the shorting block jumperPowerLogic EM4805 CT color pair identification Connecting the Communications Connecting the Phone LineConnecting the Ethernet Cable Manually Testing CommunicationsNormal Mode Diagnostics ModePulse Inputs Display NavigationRemote Display Recording the Meter MapInstallation Record sample shown Maintenance Regulatory Compliance Graphical symbols that appear on equipment Graphical symbolsShows the graphical symbols that appear on the equipment Index PowerLogicTM EM4800 Series 930-110-01-B.00 Index 04/2011 User Notes Page 930-110-01-B.00 04/2011