APPENDIX “B” - SPECIFICATIONS AND DIMENSIONS

1.DISPLAY: 4-digit with F/C indication, 0.56" (14.2 mm) high LED, minus sign displayed for negative temperatures. 6-digits for integrator/ totalizer. “Flashing” display for totalizer overflow. “ULULUL” displayed for input overload and “OLOLOL” displayed for underload (negative overload).

2.POWER REQUIREMENTS: Switch selectable 115/230 VAC, ￿10%, 50/60 Hz, 14 VA.

Isolation: 2300 Vrms for 1 min. To all inputs and outputs. Working Voltage: 300 V max., CAT II

3.CONTROLS: Three front panel push buttons for modifying alarm values and indicator set-up. Two external inputs for disabling the front panel and controlling programmable functions.

4.SIGNAL INPUT: 2-Wire, 400 Series 2,252 ohm Thermistor; or 3-wire, 700 Series Thermolinear￿ thermistor.

Max. Input Signal Voltage: ￿15 VDC.

Input Common potential with respect to earth Common: 50 V max., CAT I

5.OPEN THERMISTOR DETECTION: Display - “ULULUL”

Setpoint Outputs - Disabled (Deactivated) Serial Output - “ULULUL” in data field Integration/Totalization - Disabled Analog Output - 4 mA

6.RANGE: 400 Series -40.0￿ to ￿￿￿￿￿￿C (-40.0￿ to 257￿F￿ 700 Series -30.0￿ to 100.0￿C (-22.0￿ to 212￿F).

7.RESOLUTION: 0.1 or 1 degree.

8.ACCURACY: ￿0.2￿C (0.36￿F) ￿ 12 LSD, @ 23￿C and 10 min. warm-up.

9.READING RATE: 2.5 readings/second

10.RESPONSE TIME: 2 seconds to settle for step input (increases with programmable digital filtering)

11.NORMAL MODE REJECTION: 40 dB at 50/60 Hz (may be improved by programmable digital filtering)

12.COMMON MODE REJECTION: 120 dB, DC to 50/60 Hz

13.INTEGRATOR/TOTALIZER: Front panel button for input/total display select. External integrator/totalizer reset/enable. Programmable time-base, scale factor (0.001-999.999) and low-temp cut-out. Maximum response time 0.2 sec.

14.E1-CON & E2-CON:External remote inputs which allow activation of various functions. (Reset total, peak indicator mode, trigger mode, etc.) VIL = 0.8 VMAX; VIH = 2.0 VMIN; Response Time = 0.2 sec. Maximum.

DIMENSIONS In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.1" (53.3) H x 5.5" (140) W.

PANEL CUT-OUT

-38-

Image 40
Contents Apollo Intelligent Meter Series Introduction Table of Contents Page Safety Summary Safety InformationDefinition of Terms General Description Theory of OperationBlock Diagram Programming and Operating the IMY Programming the IMYDisplay Module #2 Program Temperature Display Offset and Slope Display Alarm Values Enter Alarm ValuesReset Latched Alarms Reset PEAK/VALLEY Memory BufferTemperature Offset Value Enter Offset ValueModule #4 Program Digital Filter and Remote Input Program Digital FilteringProgram Function of E1-CON and Optional E2-CON Cont’d Program Decimal Point Position for the INTEGRATOR/TOTALIZER Module #5 Program INTEGRATOR/TOTALIZERProgram INTEGRATOR/TOTALIZER Time Base Module #6 Program ALARM/SETPOINT Program Value for Alarm #2 Alarm #2 Assignment to Input or INTEGRATOR/ TotalizerAlarm #2 High or LOW Acting Baud Rate Unit Address NumberPrint Request Function Full or Abbreviated TransmissionModule #8 Program RE-TRANSMITTED Analog Output Analog Output SourceAnalog Output LO Display Value Analog Output HI Display ValueModule #9 Service Operations Enter Access CodeEnter Zero Reference Apply Precision ResistanceOperating the IMY Quick ProgrammingFactory Configuration SlopeProgramming Example Temperature Monitoring Example INTEGRATOR/TOTALIZER Offset and Slope Display TemperaturePEAK/VALLEY Basic SET-UP INTEGRATOR/TOTALIZER ExampleINTEGRATOR/TOTALIZER SET-UP 125 x 827 Alarms Optional Alarm Timing DiagramsGeneral Description Communication FormatSending Commands to the IMY Command String ExamplesTiming Diagrams Current Loop Installation Wiring ConnectionsReceiving Data from the IMY Serial Terminal DescriptionsConnecting to AN RLC Printer Serial Communications ExamplesProcess Controlling System RE-TRANSMITTED Analog Output Optional Analog Output Calibration To 20 mA CalibrationInstallation Environment Appendix a Installation & ConnectionsSelect AC Power 115/230 VAC EMC Installation Guidelines Wiring Connections Power WiringAppendix B Specifications and Dimensions Open Thermistor Detection Display UlululTo 20 mA Certifications and Compliances Safety Appendix C Troubleshooting Guide Problem Possible Cause RemediesAppendix D Programmable Functions Decimal Point PositonAppendix D Programmable Functions Cont’d Appendix E Ordering Information E2-CONLimited Warranty IMY/IM-A 3/02 Drawing NO. LP0311