Apollo IMY instruction manual Safety Information, Safety Summary, Definition of Terms

Page 5

SAFETY INFORMATION

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

Do not use this unit to directly command motors, valves, or other actuators not equipped with safeguards. To do so, can be potentially harmful to persons or equipment in the event of a fault to the unit.

DEFINITION OF TERMS

INSTALLATION CATEGORY (overvoltage category) I:

Signal level, special equipment or parts of equipment, telecommunication, electronic, etc. with smaller transient overvoltages than Installation Category (overvoltage category) II.

INSTALLATION CATEGORY (overvoltage category) II:

Local level, appliances, portable equipment, etc. with smaller transient overvoltages than Installation Category (overvoltage category) III.

-3-

Image 5
Contents Apollo Intelligent Meter Series Introduction Table of Contents Page Definition of Terms Safety InformationSafety Summary Theory of Operation General DescriptionBlock Diagram Programming the IMY Programming and Operating the IMYDisplay Module #2 Program Temperature Display Offset and Slope Enter Alarm Values Display Alarm ValuesReset Latched Alarms Reset PEAK/VALLEY Memory BufferEnter Offset Value Temperature Offset ValueProgram Digital Filtering Module #4 Program Digital Filter and Remote InputProgram Function of E1-CON and Optional E2-CON Cont’d Program INTEGRATOR/TOTALIZER Time Base Module #5 Program INTEGRATOR/TOTALIZERProgram Decimal Point Position for the INTEGRATOR/TOTALIZER Module #6 Program ALARM/SETPOINT Alarm #2 High or LOW Acting Alarm #2 Assignment to Input or INTEGRATOR/ TotalizerProgram Value for Alarm #2 Unit Address Number Baud RatePrint Request Function Full or Abbreviated TransmissionAnalog Output Source Module #8 Program RE-TRANSMITTED Analog OutputAnalog Output LO Display Value Analog Output HI Display ValueEnter Access Code Module #9 Service OperationsEnter Zero Reference Apply Precision ResistanceQuick Programming Operating the IMYSlope Factory ConfigurationProgramming Example Temperature Monitoring Example PEAK/VALLEY Offset and Slope Display TemperatureINTEGRATOR/TOTALIZER INTEGRATOR/TOTALIZER SET-UP INTEGRATOR/TOTALIZER ExampleBasic SET-UP 125 x 827 Alarm Timing Diagrams Alarms OptionalCommunication Format General DescriptionCommand String Examples Sending Commands to the IMYTiming Diagrams Wiring Connections Current Loop InstallationReceiving Data from the IMY Serial Terminal DescriptionsSerial Communications Examples Connecting to AN RLC PrinterProcess Controlling System RE-TRANSMITTED Analog Output Optional To 20 mA Calibration Analog Output CalibrationSelect AC Power 115/230 VAC Appendix a Installation & ConnectionsInstallation Environment EMC Installation Guidelines Power Wiring Wiring ConnectionsOpen Thermistor Detection Display Ululul Appendix B Specifications and DimensionsTo 20 mA Certifications and Compliances Safety Problem Possible Cause Remedies Appendix C Troubleshooting GuideDecimal Point Positon Appendix D Programmable FunctionsAppendix D Programmable Functions Cont’d E2-CON Appendix E Ordering InformationLimited Warranty IMY/IM-A 3/02 Drawing NO. LP0311