Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1151 |
Numbers |
|
Event ID — 2182
Description
Severity
Cause and Action
Related Alert Information
An invalid SAS configuration has been detected.
Critical / Failure / Error
Cause: The controller and attached enclosures are not cabled correctly.
Action: See the hardware documentation for information on correct cabling configurations.
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
SNMP Trap | 754 |
Numbers |
|
Event ID — 2183 | |
Description | Replace Member Operation failed on physical disk % 1 from physical disk % 2. |
Severity | Critical / Failure / Error |
Cause and | Cause: The physical disk participating in the Replace Member Operation, |
Action | operation has failed. |
| Action: None |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: 2060 |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 904 |
Numbers |
|
Event ID — 2184 | |
Description | Physical disk Replace Member Operation cancelled. |
Severity | OK / Normal / Informational |
Cause and | Cause: User cancelled the Replace Member Operation. |
Action | Action: None |
102