Table 3. Alert Message Format
Alert ID | Message Text Displayed in the Storage | Message Text Displayed in the Alert Log |
| Management Service Documentation | with Variable Information Supplied |
|
|
|
2127 | Background Initialization started | Background Initialization started: Virtual Disk |
|
| 3 (Virtual Disk 3) Controller 1 (PERC 5/E |
|
| Adapter) |
|
|
|
2334 | Controller event log % | Controller event log: Current capacity of the |
|
| battery is above threshold : Controller 1 |
|
| (PERC 5/E Adapter) |
|
|
|
The variables required to complete the message vary depending on the type of storage object and whether the storage object is in a SCSI or SAS configuration. The following table identifies the possible variables used to identify each storage object.
NOTE: Some alert messages relating to an enclosure or an enclosure component, such as a fan or EMM, are generated by the controller when the enclosure or enclosure component ID cannot be determined.
NOTE: A, B, C and X, Y, Z in the following examples are variables representing the storage object name or number.
Table 4. Message Format with Variables for Each Storage Object
Storage Object | Message Variables |
|
|
Controller | Message Format: Controller A (Name) |
| Message Format: Controller A |
| For example, 2326 A foreign configuration has been detected: Controller 1 |
| (PERC 5/E Adapter) |
| NOTE: The controller name is not always displayed. |
Battery | Message Format: Battery X Controller A |
| For example, 2174 The controller battery has been removed: Battery 0 |
| Controller 1 |
SCSI Physical Disk | Message Format: Physical Disk X:Y Controller A, Connector B |
| For example, 2049 Physical disk removed: Physical Disk 0:14 Controller 1, |
| Connector 0 |
SAS Physical Disk | Message Format: Physical Disk X:Y:Z Controller A, Connector B |
| For example, 2049 Physical disk removed: Physical Disk 0:0:14 Controller 1, |
| Connector 0 |
Virtual Disk
Enclosure
SCSI Power Supply
56
Message Format: Virtual Disk X (Name) Controller A (Name)
Message Format: Virtual Disk X Controller A
For example, 2057 Virtual disk degraded: Virtual Disk 11 (Virtual Disk 11) Controller 1 (PERC 5/E Adapter)
NOTE: The virtual disk and controller names are not always displayed.
Message Format: Enclosure X:Y Controller A, Connector B
For example, 2112 Enclosure shutdown: Enclosure 0:2 Controller 1, Connector 0
Message Format: Power Supply X Controller A, Connector B, Target ID C