| Action: None |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: 2127 |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1201 |
Numbers |
|
Event ID — 2282 | |
Description | Hot spare SMART polling failed. |
Severity | Critical / Failure / Error |
Cause and | Cause: The controller firmware attempted a SMART polling on the hot spare but |
Action | was unable to complete it. The controller has lost communication with the hot |
| spare. |
| Action: Check the health of the disk assigned as a hot spare. You may need to |
| replace the disk and reassign the hot spare. Make sure the cables are attached |
| securely. See the Server Administrator Storage Management User’s Guide, for more |
| information on checking the cables. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: 2071 |
SNMP Trap | 904 |
Numbers |
|
Event ID — 2283 | |
Description | A redundant path is broken. |
Severity | Warning / |
Cause and | Cause: The controller has two connectors that are connected to the same |
Action | enclosure. The communication path on one connector has lost connection with |
| the enclosure. The communication path on the other connector is reporting this |
| loss. |
| Action: Make sure the cables are attached securely and both enclosure |
| management modules (EMMs) are healthy. See the Cables Attached Correctly |
| section for more information on checking the cables. |
Related Alert | Clear Alert Number: 2284 |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: 2070 |
SNMP Trap | 903 |
Numbers |
|
135