Event ID — 2092
Description | Physical disk rebuild completed. |
Severity | OK / Normal / Informational |
Cause and | Cause: This alert is for informational purposes. |
Action | Action: None |
Related Alert | Clear Alert Number: Alert 2092 is a clear alert for alert 2065. |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 901 |
Numbers |
|
Event ID — 2094 | |
Description | Predictive Failure reported. |
Severity | Warning / |
Cause and | Cause: The physical disk is predicted to fail. Many physical disks contain Self |
Action | Monitoring Analysis and Reporting Technology (SMART). When enabled, SMART |
| monitors the health of the disk based on indications such as the number of write |
| operations that have been performed on the disk. |
| Action: Replace the physical disk. Even though the disk may not have failed yet, it is |
| strongly recommended that you replace the disk. |
| If this disk is part of a redundant virtual disk, perform the Offline task on the disk; |
| replace the disk; the rebuild starts automatically. |
| NOTE: If you put the drive in a different slot, you need to assign it as a hot |
| spare for the rebuild to start automatically. |
| If this disk is a hot spare, then unassign the hot spare; perform the Prepare to |
| Remove task on the disk; replace the disk; and assign the new disk as a hot spare. |
| CAUTION: If this disk is part of a |
| immediately. If the disk fails, you cannot recover the data. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| |
| Local Response Agent (LRA) Number: 2070 |
SNMP Trap | 903 |
Numbers |
|
Event ID — 2095 | |
Description | SCSI sense data %1. |