Event ID — 2381
Description | Controller preserved cache is recovered. |
Severity | OK / Normal / Informational |
Cause and | Cause: This alert is provided for informational purposes. |
Action | Action: None. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 751 |
Numbers |
|
Event ID — 2382 | |
Description | An unsupported configuration was detected. The controller does not support |
| physical disks of type SSD: <Physical DiskID>, <controller- ID>, <connector- ID> |
Severity | Warning / |
Cause and | Cause: A physical disk of media type SSD is attached to a controller that does not |
Action | support SSD disks. |
| Action: Replace the unsupported physical disk with a physical disk of media type |
| HDD. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 903 |
Numbers |
|
Event ID — 2383 | |
Description | The Information level set for the hot spare protection policy is violated for the |
| Virtual Disk. |
Severity | OK / Normal / Informational |
Cause and | Cause: The number of physical disks you specified for the hot spare protection |
Action | policy is violated. |
| Action: Reassign the number of hot spares as specified in the protection policy for |
| that RAID level. |
Related Alert | Clear Alert Number: 2195 |
Information | Related Alert Number: None |
Local Response Agent (LRA) Number: None
169