Dell 7.4 manual Viewing Alerts and Event Messages, Logging Messages to a Unicode Text File

Page 21

Data: Bytes in Hex

Viewing Alerts and Event Messages

An event log is used to record information about important events.

Server Administrator generates alerts that are added to the operating system event log and to the Server Administrator alert log. To view these alerts in Server Administrator:

1.Select the System object in the tree view.

2.Select the Logs tab.

3.Select the Alert tab.

You can also view the event log using your operating system’s event viewer. Each operating system’s event viewer accesses the applicable operating system event log.

The location of the event log file depends on the operating system you are using.

On systems running the Microsoft Windows operating systems, event messages are logged in the operating system event log and the Server Administrator event log.

NOTE: The Server Administrator event log file is named dcsys32.xml and is located in the <install_path>\omsa\log directory. The default install_path is C:\Program Files\Dell\SysMgt.

On systems running the Red Hat Enterprise Linux, SUSE Linux Enterprise Server, Citrix XenServer, VMware ESX, and VMware ESXi operating systems, the event messages are logged in the operating system log file and the Server Administrator event log.

NOTE: The default name of the operating system log file is /var/log/messages, and you can view the operating system log file using a text editor such as vi or emacs. The Server Administrator event log file is named dcsys<xx>.xml,where xx is either 32 or 64 bit depending on the operating system. In the Red Hat Enterprise Linux, SUSE Linux Enterprise Server, Citrix XenServer and VMware ESX operating systems, the Server Administrator event log file is located in the /opt/ dell/srvadmin/var/log/openmanage directory. In the VMware ESXi operating system, the Server Administrator event log file is located in the /etc/cim/dell/srvadmin/log/openmanage directory.

Logging Messages to a Unicode Text File

Logging messages to a Unicode text file is optional. By default, the feature is disabled in the Server Administrator. To enable this feature, modify the Event Manager section of the dcemdy <xx>.ini configuration file where xx is 32 or 64 bit depending on the operating system, as follows:

On systems running Microsoft Windows operating systems, you can locate the configuration file in the <install_path> \dataeng\ini directory and set the property UnitextLog.enabled=true. The default install_path is C:\Program Files\Dell\SysMgt. Restart the DSM SA Event Manager service to enable the setting. The Server Administrator Unicode text event log file is named dcsys32.log and is located in the <install_path>\omsa\log directory.

On systems running the Red Hat Enterprise Linux, SUSE Linux Enterprise Server, Citrix XenServer and VMware ESX operating systems, you can locate the configuration file in the /opt/dell/srvadmin/etc/ srvadmin-deng/ini directory and set the property UnitextLog.enabled=true. Run the /etc/init.d/ dataeng restart command to restart the Server Administrator Event Manager service and enable the setting. This also restarts the Server Administrator Data Manager and SNMP services. The Server Administrator Unicode text event log file is named dcsys <xx>.log where xx is 32 or 64 bit depending on the operating system and is located in the /opt/dell/srvadmin/var/log/ openmanage directory.

On systems running the in ESXi operating system the dcemdy32.ini file is located under /etc/cim/ dell/srvadmin/srvadmin-deng/ini/ and the dcsys <xx>.log where xx is 32 or 64 bit depending on the operating system and is located under /etc/cim/dell/srvadmin/log/openmanage/

The following sub-sections explain how to launch the Windows Server 2008, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESX, and VMware ESXi event viewers.

21

Image 21
Contents Server Administrator Version 7.4 Messages Reference Guide Page Contents Page Page Storage Management Message Reference Event ID 100 103 117 131 147 162 177 System Event Log Messages for Ipmi Systems 226 Alert Message Change History What’s New in this Release2415, 2416, 2417 Understanding Event Messages Messages Not Described in This GuideSample Event Message Text Logging Messages to a Unicode Text File Viewing Alerts and Event MessagesViewing Events in Microsoft Windows Server Understanding the Event Description Configuration error type Revision mismatch For example Memory device bank location Bank1 For example Redundancy unit Fan Enclosure Server Management Messages Server Administrator General MessagesAutomatic System Recovery ASR action was performed Action RCI table is corrupt Watts Reading Temperature Sensor MessagesTemperature sensor value in degrees Celsius Reading Temperature sensor detected a failure value Sensor location Cooling Device Messages Voltage Sensor Messages Sensor value information is provided Value information is provided Current Sensor Messages Description Severity Chassis Intrusion Messages Redundancy Unit Messages Redundancy sensor value unknown Redundancy unit Redundancy Power Supply Messages Power supply returned to normal Sensor Location Location Memory Device Messages Hardware Log Sensor Messages Log monitoring has been disabled Processor Sensor Messages Pluggable Device Messages Battery Sensor Messages SeverityError Secure Digital SD Card Device Messages SD card device returned to normal Sensor location Location Chassis Management Controller Messages Description CMC reported a warning Severity Cause Alert Message Format with Substitution Variables Alert Monitoring and LoggingAlert Message Format Scsi EMM Alert Descriptions and Corrective ActionsRelated Alert Online operation Event ID Virtual disk failed Event ID Snmp Trap 901 Numbers Virtual disk rebuild started Virtual disk initialization cancelled Virtual disk Check Consistency failed Physical disk initialization failed Virtual disk rebuild failed Related Alert Information Snmp Trap Numbers Event ID Physical disk rebuild completed Global hot spare assigned Temperature exceeded the maximum warning threshold Temperature dropped below the minimum failure threshold Cause and Action Related Alert Information Snmp Trap Numbers Smart warning Smart warning degraded Minimum allowable temperature range Virtual disk and its mirror have been split Enclosure firmware mismatch Redundancy lost Redundancy normal Description BGI failed Severity Critical / Failure / Error BGI completed Manager installation Communication time-out Enclosure alarm disabled Controller rebuild rate has changed Snmp Trap 751 Numbers Bad block medium error Enclosure asset tag changed Maximum temperature probe warning threshold value changed Controller configuration has been reset Dedicated hot spare assigned Communication regained 101 Meet the minimum requirements 1154 Snmp Trap 1151 Numbers Controller battery Learn cycle has started Controller battery Learn cycle has been postponed Snmp Trap 754 Numbers Physical disk Replace Member Operation stopped for spare Controller write policy has been changed to Write Through Configuration 106 Snmp Trap 903 Numbers Virtual disk Global hot spare has been removed Dedicated hot spare has been automatically unassigned New disk as a hot spare Recharge count maximum exceeded 113 None of the Controller Property are set 115 116 117 118 119 120 Foreign configuration has been cleared Patrol Read operation has started Virtual disk blink has ceased 124 125 126 Snmp Trap 851 Numbers Snmp Trap 101 Numbers Device is missing 751, 801, 851, 901, 951, 1001, 1051, 1101, 1151 Physical disk Clear operation failed Patrol Read found an uncorrectable media error Dedicated hot spare is too small Cycle. This alert is provided for informational purposes Hot spare Smart polling failed 136 Protection policy has been changed 754 EMM has failed Snmp Trap 854 Numbers Bad PHY %1 Enclosure is not responding Physical disk is too small to be used for a rebuild Bad block table is full. Unable to log block %1 Possible because there is no redundancy Severity Cause and Action Health is poor Dimm Supply unit or it is defective Management User’s Guide for more information Nvram has corrupt data Bad disk block has been reassigned Controller event log %1 Discharged BGI completed with uncorrectable errors Lost Error occurred %1 Rebuild failed due to errors on the target physical disk Operation Enclosure temperature has returned to normal SAS SMP Communications error %1 162 State during the next system reboot Protocols SATA/SAS is not supported on the same virtual disk 165 Attempted import of unsupported Virtual Disk type RAID %1 Attempted import of Virtual Disk with missing physical disk Snmp Trap 753 Numbers HDD Drive could not be assigned as Dedicated Hot Spare Virtual disk bad block medium error is detected 172 Virtual disk is encrypted Restart the check consistency operation Physical Disk Power status changed from 1% to 2% Snmp Trap 904 Numbers 177 178 Controller battery is discharging Disk medium error on virtual disk has been corrected 181 Physical Device Full Initialization completed 183 184 Critical temperature threshold of the device was exceeded 186 187 188 189 190 191 192 193 Local Response Agent LRA Number None 194 Snmp Trap 1604 Numbers 196 197 Action Related Alert Configured mode. FluidCache 200 System Event Log Messages for Ipmi Systems Temperature Sensor EventsVoltage Sensor Events Fan Sensor Events Fan sensor returned to Fans are redundant Processor Status EventsDisabled Processor Entity status Power Supply Events Name predictive failure Asserted PS 1 Status Power supply Supply number is Dimm Memory ECC EventsBMC Watchdog Events System rebootMemory Events Memory RAID redundancy is Drive Events Hardware Log Sensor EventsIntrusion sensor Name Intrusion EventsOFF Bios Generated System EventsSystem Event PCI System Memory Removed BANK# SBE Log Disabled An I/O channel check Fatal IO error detected An OEM diagnostic event Post Code Table Page Cable Interconnect Events Operating System Generated System EventsBattery Events Power And Performance Events Degraded because Miscellaneous Events Entity Presence EventsBMC firmware was Asserted Hdwar version err QuickPath