SNMP Trap | 1151 |
Numbers |
|
Event ID — 2173 | |
Description | Unsupported configuration detected. The SCSI rates of the enclosure management |
| modules (EMMs) are not the same. EMM 0 % 1 EMM 1 % 2 |
Severity
Cause and Action
Related Alert Information
SNMP Trap Numbers
Warning /
Cause: An unsupported configuration was detected.
Action: Replace one of the EMMs with the matching SCSI rate EMM.
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2090
853
Event ID — 2174
Description | The controller battery has been removed. |
Severity | Warning / |
Cause and | Cause: The controller cannot communicate with the battery. The battery may be |
Action | removed, or the contact point between the controller and the battery may be burnt |
| or corroded. |
| Action: Replace the battery if it has been removed. If the contact point between |
| the battery and the controller is burnt or corroded, you must replace either the |
| battery or the controller, or both. See the hardware documentation for information |
| on how to safely access, remove, and replace the battery. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: 2188, 2318 |
| Local Response Agent (LRA) Number: 2100 |
SNMP Trap | 1153 |
Numbers |
|
Event ID — 2175 | |
Description | The controller battery has been replaced. |
Severity | OK / Normal / Informational |
Cause and | Cause: This alert is for informational purposes. |
Action | Action: None |
99