SNMP Trap | 1154 |
Numbers |
|
Event ID — 2170 | |
Description | The controller battery charge level is normal. |
Severity | OK / Normal / Informational |
Cause and | Cause: This alert is for informational purposes. |
Action | Action: None |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1151 |
Numbers |
|
Event ID — 2171 | |
Description | The controller battery temperature is above normal. |
Severity | Warning / |
Cause and | Cause: The battery may be recharging, the room temperature may be too hot, or |
Action | the fan in the system may be degraded or failed. |
| Action: If this alert was generated due to a battery recharge, the situation is |
| corrected when the recharge is complete. You should also check if the room |
| temperature is normal and that the system components are functioning properly. |
Related Alert | Clear Alert Number: 2172 |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: 2100 |
SNMP Trap | 1153 |
Numbers |
|
Event ID — 2172
Description
Severity
Cause and Action
Related Alert Information
The controller battery temperature is normal.
OK / Normal / Informational
Cause: This alert is for informational purposes.
Action: None
Clear Alert Number: Alert 2172 is a clear alert for alert 2171.
Related Alert Number: None
Local Response Agent (LRA) Number: None
98