Severity | Warning / |
Cause and | Cause: The version of the kernel and the driver do not meet the minimum |
Action | requirements. Storage Management may not be able to display the storage or |
| perform storage management functions until you have updated the system to |
| meet the minimum requirements. |
| Action: See the Readme file for a list of validated kernel and driver versions. Update |
| the system to meet the minimum requirements and then reinstall Storage |
| Management. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: 2050 |
SNMP Trap | 103 |
Numbers |
|
Event ID — 2168 | |
Description | The |
| readme.txt for the validated driver version. |
Severity | Warning / |
Cause and | Cause: The version of the driver does not meet the minimum requirements. |
Action | Storage Management may not be able to display the storage or perform storage |
| management functions until you have updated the system to meet the minimum |
| requirements. |
| Action: See the Readme file for the validated driver version. Update the system to |
| meet the minimum requirements and then reinstall Storage Management. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: 2050 |
SNMP Trap | 103 |
Numbers |
|
Event ID — 2169 | |
Description | The controller battery needs to be replaced. |
Severity | Critical / Failure / Error |
Cause and | Cause: The controller battery cannot be recharged. The battery may be old or it |
Action | may have been already recharged the maximum number of times. In addition, the |
| battery charger may not be working. |
| Action: Replace the battery pack. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: 2118 |
| Local Response Agent (LRA) Number: 2101 |
97