redundancy unit location, chassis location, previous redundancy state, and the number of devices required for full redundancy information is provided.
Event ID — 1305
Description | Redundancy degraded Redundancy unit: <Redundancy Location in |
| chassis> |
| Chassis location: <Name of chassis> |
| Previous redundancy state was: <State> |
Severity | Warning |
Cause | A redundancy sensor in the specified system detected that one of the components |
| of the redundancy unit has failed but the unit is still redundant. The redundancy |
| unit location, chassis location, previous redundancy state, and the number of |
| devices required for full redundancy information is provided. |
Event ID — 1306
Description | Redundancy lost Redundancy unit: <Redundancy Location in |
| chassis> |
| Chassis location: <Name of chassis> |
| Previous redundancy state was: <State> |
Severity | Error |
Cause | A redundancy sensor in the specified system detected that one of the components |
| in the redundant unit has been disconnected, has failed, or is not present. The |
| redundancy unit location, chassis location, previous redundancy state, and the |
| number of devices required for full redundancy are provided. |
Power Supply Messages
The power supply sensors monitor how well a power supply is functioning. The power supply messages listed provides status and warning information for power supplies present in a particular chassis.
Event ID — 1351
Description Power supply sensor value unknown Sensor Location: <Location in chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Power Supply type: <type of power supply> <Additional power supply status information> If in configuration error state:
Configuration error type:<type of configuration error>
SeverityWarning
42