Related Alert | Clear Alert Number: None |
Information | Related Alert Number: 2199 |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1153 |
Numbers |
|
Event ID — 2279 | |
Description | The controller battery charge level is operating within normal limits. |
Severity | OK / Normal / Informational |
Cause and | Cause: This alert indicates that the battery is recharging during the battery Learn |
Action | cycle. This alert is provided for informational purposes. |
| Action: None |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1151 |
Numbers |
|
Event ID — 2280 | |
Description | A disk media error has been corrected. |
Severity | OK / Normal / Informational |
Cause and | Cause: A disk media error was detected while the controller was completing a |
Action | background task. A bad disk block was identified. The disk block has been |
| remapped. |
| Action: Consider replacing the disk. If you receive this alert frequently, be sure to |
| replace the disk. You should also routinely back up your data. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1201 |
Numbers |
|
Event ID — 2281 | |
Description | Virtual disk has inconsistent data. |
Severity | OK / Normal / Informational |
Cause and | Cause: The virtual disk has inconsistent data. This may be caused when a power |
Action | loss or system shutdown occurs while data is being written to the virtual disk. This |
| alert is for informational purposes. |
134