Event ID — 2162
Description | Communication regained. |
Severity | OK / Normal / Informational |
Cause and | Cause: Communication with an enclosure has been restored. This alert is for |
Action | informational purposes. |
| Action: None |
Related Alert | Clear Alert Number: Alert 2162 is a clear alert for alerts 2137 and 2292. |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 851 |
Numbers |
|
Event ID — 2163 | |
Description | Rebuild completed with errors. |
Severity | OK / Normal / Informational |
Cause and | Cause: During a rebuild one or more blocks of data was not recoverable due to |
Action | missing parity information. Some data loss may have occurred. |
| Action: Perform a check to verify the built array. Any files that are impacted should |
| be restored from a backup. See the Storage Management online help for more |
| information. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: 2071 |
SNMP Trap | 904 |
Numbers |
|
Event ID — 2164 | |
Description | See the Readme file for a list of validated controller driver versions. |
Severity | OK / Normal / Informational |
Cause and | Cause: Storage Management is unable to determine whether the system has the |
Action | minimum required versions of the RAID controller drivers. This alert is for |
| informational purposes. |
| Action: See the Readme file for driver and firmware requirements. In particular, if |
| Storage Management experiences performance problems, you should verify that |
| you have the minimum supported versions of the drivers and firmware installed. |
Related Alert | Clear Alert Number: None |