SNMP Trap | 1203 |
Numbers |
|
Event ID — 2345 | |
Description | The virtual disk initialization failed. |
Severity | Critical / Failure / Error |
Cause and | Cause: The controller cannot communicate with attached devices. A disk may be |
Action | removed or contain errors. Cables may also be loose or defective. |
| Action: Verify the health of attached devices. Review the Alert Log for significant |
| events. Make sure the cables are attached securely. See the Cables Attached |
| Correctly section for more information on checking the cables. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: 2081 |
SNMP Trap | 1204 |
Numbers |
|
Event ID — 2346 | |
Description | Error occurred: %1. |
Severity | Warning / |
Cause and | Cause: A physical device may have an error. The %1 indicates a substitution |
Action | variable. The text for this substitution variable is generated by the firmware and is |
| displayed with the alert in the alert log. This text can vary depending on the |
| situation. |
| Action: Verify the health of attached devices. Review the alert log for significant |
| events. Run the PHY integrity diagnostic tests. You may need to replace faulty |
| hardware. Make sure that the cables are attached securely. See the hardware |
| documentation for more information. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: 2048, 2050, 2056, 2057, 2076, 2079, 2081, 2083, 2095, |
| 2129, 2201, 2203, 2270, 2282, 2369 |
| Local Response Agent (LRA) Number: 2070 |
SNMP Trap | 903 |
Numbers |
|
Event ID — 2347 | |
Description | The rebuild failed due to errors on the source physical disk. |
Severity | Critical / Failure / Error |
157