Furuno FR-2115/2125 manual Changing AC Power Specification, How to attach NH connector

Page 32

How to attach NH connector

HOW TO ATTACH NH CONNECTOR TO SIGNAL CABLE

NH connector wire

NH connector housing

1Insert NH connector wire into NH connector housing.

Shrink tubing

20mm

2Cut shrink tubing in 20 mm lengths and slip onto each wire.

Solder

 

3 Solder connector

4Heat shrink

to signal cable.

tubing with solder-

 

ing iron.

Figure 2-16 How to attach NH connector

2.3 Changing AC Power Specification

For 100 VAC or 220 VAC power, add or delete jumper wires on the PTU Board and change the power fuses inside the display unit as shown in the table below accord- ing to ship’s mains. The figure below shows the location of the power fuses and the jumper wires on the PTU Board.

Table 2-2 Jumper wire setting on the PTU board, fuse rating and power specification

PCB

Power Spec.

Antenna

JP1

JP2

JP3

JP4

JP91

JP92

Power

rpm

Fuses

 

 

 

 

 

 

 

 

03P9245A

100/110/115 VAC

24 rpm

YES

YES

YES

NO

NO

NO

10A

03P9245C

100/110/115 VAC

42 rpm

YES

YES

YES

NO

YES

YES

 

03P9245D

220/230 VAC

24 rpm

NO

NO

NO

YES

NO

NO

5A

03P9245F

220/230 VAC

42 rpm

NO NO NO

YES

YES

YES

 

 

 

Jumper wire to use:

 

 

 

 

 

 

 

JP1: 0.8 dia. gilded wire

 

 

 

 

 

 

JP2, JP3, JP4, JP91, JP92: type ERD-S2TCOV

 

Fuse

03P9245

C11 C12

JP1

 

 

 

T1

 

JP2

 

JP92

 

 

 

 

JP3

JP92

 

 

 

 

 

U92

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JP4

 

 

 

 

JP91

 

 

 

 

 

 

T21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PTU Board

Figure 2-17 Display unit, inside view

2-12

Image 32
Contents Marine Radar B . N o . I M E 3 4 6 4 0 M Safety Instructions Power Switch in AC Powered Display Unit Power SwitchTable of Contents Equipment Lists Standard SupplyOptional Equipment Name Type Code No Qty RemarksSystem Configuration Scanner Unit Mounting considerationsBe sure to remove the guide pins Assembling the scanner unitFastening the scanner unit to the mounting platform Fastening the radiator to the radiator bracketScanner unit, front view Mounting procedure Display UnitBefore mounting the display unit Tabletop mountingStay Setting catch to hole in stay 11 How to dismount the PTU cover Console type mountingSeparate type control head kit Type OP03-151, No Display unit modification procedureSeparating the control head Control head modification procedure 13 Detaching the control headPlate Connection of display unit to control head15 How to attach KB fixing plate Attachment of hoodWiring Scanner unit, front view, cover removed Correct seating of waterproofing gasket Fabricating signal cable S03-75 Fabricating signal cable S03-74 =EMI cores Outer cores RFC-13 thick Inner cores RFC-10 thinFabricating the AC power cable supplied DPYCY-3.5Fabricating the DC power cable CVV-S 8 x 2C, option CVV-S 82CCable fed from rear of display unit Default Leading in cables to the display unitCable fed from outside display unit Cables fed from bottom of display unit for console mountConnections M4X8 2 pcsConnectors on the INT Board Connectors on the INT BoardChanging AC Power Specification How to attach NH connectorTuning Initialization Accessing Menus for Initialization and AdjustmentAdjusting Video Signal Level Restoring default settingsHeading Alignment Picture appears Deviated counterclockwiseAdjusting Sweep Timing Suppressing Main BangConfirming Magnetron Heater Voltage Magnetron heater voltage ratingInitial Setting Menus Press Radar Menu 0 0 0Initial SETTING3 menu Initial SETTING1 menuInitial SETTING2 menu Initial SETTING4 menu OWN Ship Information menuInstallation and connection of the Gyro Converter Board Gyro Converter GC-8Gyro Converter Board 64P1106 Default setting Connection of external power supplyDIP switch, jumper wire settings Setting method 1 by gyrocompass specifications Gyrocompass type FrequencySetting method 2 by make and model of gyrocompass JP1 JP2 JP3 JP4 JP5Setting the heading readout on the radar display SW1Installation of the ARP board ARP Board ARP-26ARP board adjustment ARP Board 18P9002BFinal check ARP Board ARP-26RP Board RP-26 Table top/console type10 Display pedestal Separate type control head Necessary parts RP-26-Z-2E Code no13 Display pedestal, front view Performance Monitor PM-30 Necessary parts PM-30 and OP03-150 Code noNecessary parts OP03-156 Code no Alarm KitProcedure 16 Display unit, inside view AC-DC Conversion Kit Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page