Furuno FR-2115/2125 manual Adjusting Sweep Timing, Suppressing Main Bang

Page 35

3.5 Adjusting Sweep Timing

Sweep timing differs with respect to the length of the signal cable between the scanner unit and the display unit. Adjust sweep timing at installation to prevent the following symptoms:

The echo of a "straight" target (for example, pier), on the 0.25 nm range, will appear on the display as being pulled inward or pushed outward. See Figure 3-3.

The range of target echoes will also be incorrectly shown.

(1) Correct

(2) Target pushed

(3) Target pushed

 

inward

outward

Figure 3-3 Examples of correct and incorrect sweep timings

1.Turn on the power. Press [RADAR MENU] [0] [0] [0] [2] [3] to select TIMING ADJ on the INITIAL SETTING1 menu.

2.Transmit on the 0.25 nm range.

3.Adjust radar picture controls to display picture properly.

4.Select a target echo which should be displayed straightly.

5.Adjust the VRM control to straighten the target echo.

6.Press [ENTER].

3.6Suppressing Main Bang

If main bang appears at the screen center, suppress it as follows.

1.Turn on the power. Transmit on a long range and then wait ten minutes.

2.Adjust [GAIN] control to show a slight amount of noise on the display.

3.Select the 0.25 nm range. Adjust the [A/C SEA] control to suppress sea clut- ter.

4.Press [RADAR MENU] [0] [0] [0] [2] to open the INITIAL SETTING1 menu.

5.Press [7] to select 7.MBS.

6.Adjust the VRM control to adjust timing; the EBL control to adjust level.

7.Press [ENTER].

3-3

Image 35
Contents Marine Radar B . N o . I M E 3 4 6 4 0 M Safety Instructions Power Switch Power Switch in AC Powered Display UnitTable of Contents Standard Supply Equipment ListsName Type Code No Qty Remarks Optional EquipmentSystem Configuration Mounting considerations Scanner UnitAssembling the scanner unit Be sure to remove the guide pinsFastening the radiator to the radiator bracket Fastening the scanner unit to the mounting platformScanner unit, front view Tabletop mounting Mounting procedureDisplay Unit Before mounting the display unitStay Setting catch to hole in stay Console type mounting 11 How to dismount the PTU coverSeparate type control head kit Type OP03-151, No Display unit modification procedureSeparating the control head 13 Detaching the control head Control head modification procedureConnection of display unit to control head PlateAttachment of hood 15 How to attach KB fixing plateWiring Scanner unit, front view, cover removed Correct seating of waterproofing gasket Fabricating signal cable S03-75 =EMI cores Outer cores RFC-13 thick Inner cores RFC-10 thin Fabricating signal cable S03-74DPYCY-3.5 Fabricating the AC power cable suppliedCVV-S 82C Fabricating the DC power cable CVV-S 8 x 2C, optionLeading in cables to the display unit Cable fed from rear of display unit DefaultCables fed from bottom of display unit for console mount Cable fed from outside display unitM4X8 2 pcs ConnectionsConnectors on the INT Board Connectors on the INT Board How to attach NH connector Changing AC Power SpecificationRestoring default settings Tuning InitializationAccessing Menus for Initialization and Adjustment Adjusting Video Signal LevelPicture appears Deviated counterclockwise Heading AlignmentSuppressing Main Bang Adjusting Sweep TimingMagnetron heater voltage rating Confirming Magnetron Heater VoltagePress Radar Menu 0 0 0 Initial Setting MenusInitial SETTING3 menu Initial SETTING1 menuInitial SETTING2 menu OWN Ship Information menu Initial SETTING4 menuGyro Converter GC-8 Installation and connection of the Gyro Converter BoardGyro Converter Board 64P1106 Default setting Connection of external power supplyDIP switch, jumper wire settings Gyrocompass type Frequency Setting method 1 by gyrocompass specificationsJP1 JP2 JP3 JP4 JP5 Setting method 2 by make and model of gyrocompassSW1 Setting the heading readout on the radar displayARP Board ARP-26 Installation of the ARP boardARP Board 18P9002B ARP board adjustmentARP Board ARP-26 Final checkTable top/console type RP Board RP-2610 Display pedestal Necessary parts RP-26-Z-2E Code no Separate type control head13 Display pedestal, front view Necessary parts PM-30 and OP03-150 Code no Performance Monitor PM-30Necessary parts OP03-156 Code no Alarm KitProcedure 16 Display unit, inside view AC-DC Conversion Kit Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page