3.Adjust R21 on the INT Board so the value of TP6 is 4 Vpp. (For remote dis- play, adjust R134 on the INT Board.)

TP1

R134

TP6

R21

INT Board (03P9252)

Figure 3-1 Display pedestal

3.4 Heading Alignment

You have mounted the scanner unit facing straight ahead in the direction of the bow. Therefore, a small but conspicuous target dead ahead visually should ap- pear on the heading line (zero degrees).

In practice, you will probably observe some small bearing error on the display because of the difficulty in achieving accurate initial positioning of the scanner unit. The following adjustment will compensate for this error.

Correct bearing

a

Apparent position

b

relative to heading

 

of target

 

a

Target

320

350

000

010

040

b

Target

 

 

340

020

 

 

 

 

330

 

 

 

030

 

 

 

 

310

 

 

 

050

 

 

 

 

300

 

 

 

060

 

 

 

 

290

 

 

 

070

 

 

 

 

280

 

 

 

080

Apparent

 

 

 

260

 

 

 

100

 

 

 

270

 

 

 

090

 

 

 

 

250

 

 

 

110

position

 

 

 

240

 

 

 

120

of target

 

 

 

230

 

 

 

130

 

 

 

220

 

 

 

140

 

 

 

 

210

 

 

 

150

 

 

 

 

200

190

180

170

160

 

 

Scanner mounted

Picture appears

Scanner mounted

error to port

deviated clockwise.

error to starboard

(HDG SW advanced)

 

(HDG SW delayed)

Figure 3-2 Heading alignment

340

350

000

010

020

 

330

 

 

 

030

 

320

 

 

 

040

 

310

 

 

 

050

 

300

 

 

 

060

 

290

 

 

 

070

 

280

 

 

 

080

 

270

 

 

 

090

Correct

260

 

 

 

100

250

 

 

 

110

bearing

240

 

 

 

120

relative to

230

 

 

 

130

220

 

 

 

140

 

 

 

heading

210

 

 

 

150

200

190

180

170

160

Picture appears

deviated counterclockwise.

1.Press [RADAR MENU] [0] [0] [0] [2] [2] to select HL ALIGN on the INITIAL SETTING1 menu.

2.Select a target echo (by gyrocompass, for example) at a range between 0.125 and 0.25 nm, preferably near the heading line.

3.Operate the EBL control to bisect the target echo with the heading line. (The value shown on the display is scanner position in relation to ship's bow.)

4.Press [ENTER] to finish.

3-2

Image 34
Contents Marine Radar B . N o . I M E 3 4 6 4 0 M Safety Instructions Power Switch in AC Powered Display Unit Power SwitchTable of Contents Equipment Lists Standard SupplyOptional Equipment Name Type Code No Qty RemarksSystem Configuration Scanner Unit Mounting considerationsBe sure to remove the guide pins Assembling the scanner unitFastening the scanner unit to the mounting platform Fastening the radiator to the radiator bracketScanner unit, front view Before mounting the display unit Mounting procedureDisplay Unit Tabletop mountingStay Setting catch to hole in stay 11 How to dismount the PTU cover Console type mountingSeparating the control head Display unit modification procedureSeparate type control head kit Type OP03-151, No Control head modification procedure 13 Detaching the control headPlate Connection of display unit to control head15 How to attach KB fixing plate Attachment of hoodWiring Scanner unit, front view, cover removed Correct seating of waterproofing gasket Fabricating signal cable S03-75 Fabricating signal cable S03-74 =EMI cores Outer cores RFC-13 thick Inner cores RFC-10 thinFabricating the AC power cable supplied DPYCY-3.5Fabricating the DC power cable CVV-S 8 x 2C, option CVV-S 82CCable fed from rear of display unit Default Leading in cables to the display unitCable fed from outside display unit Cables fed from bottom of display unit for console mountConnections M4X8 2 pcs Connectors on the INT Board Connectors on the INT BoardChanging AC Power Specification How to attach NH connectorAdjusting Video Signal Level Tuning InitializationAccessing Menus for Initialization and Adjustment Restoring default settingsHeading Alignment Picture appears Deviated counterclockwiseAdjusting Sweep Timing Suppressing Main BangConfirming Magnetron Heater Voltage Magnetron heater voltage ratingInitial Setting Menus Press Radar Menu 0 0 0Initial SETTING2 menu Initial SETTING1 menuInitial SETTING3 menu Initial SETTING4 menu OWN Ship Information menuInstallation and connection of the Gyro Converter Board Gyro Converter GC-8Gyro Converter Board 64P1106 DIP switch, jumper wire settings Connection of external power supplyDefault setting Setting method 1 by gyrocompass specifications Gyrocompass type FrequencySetting method 2 by make and model of gyrocompass JP1 JP2 JP3 JP4 JP5Setting the heading readout on the radar display SW1Installation of the ARP board ARP Board ARP-26ARP board adjustment ARP Board 18P9002BFinal check ARP Board ARP-26RP Board RP-26 Table top/console type10 Display pedestal Separate type control head Necessary parts RP-26-Z-2E Code no13 Display pedestal, front view Performance Monitor PM-30 Necessary parts PM-30 and OP03-150 Code noProcedure Alarm KitNecessary parts OP03-156 Code no 16 Display unit, inside view AC-DC Conversion Kit Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page