Furuno FR-2115/2125 manual Connection of external power supply, DIP switch, jumper wire settings

Page 42

Connection of external power supply

An external power supply is necessary when the repeater signal is step-by-step type and the step voltage is below 20V or output voltage is less than 5 W.

1.Cut jumper wire JP1 on the GYRO CONVERTER Board when an external power supply is used.

2.Connect gyro cable and power cable as shown below.

External Power Supply 20 - 135 VAC

20100 VDC

Gyrocompass (Step type)

A64P1106

J5

1 R2

2 R1/COM

Either connection in case of DC polarity.

S1

J4

1 S1

S2

2 S2

 

S3

3 S3

COM

4 T

F.G.

5 F.G.

 

Figure 4-3 Connection of external power supply to GYRO CONVERTER Board

DIP switch, jumper wire settings

Default setting

The default setting of all DIP switches is off and all jumpers wire are set to “#1.” (Note that jumper wire JP1 is set at #1, #2, and #3.) In those settings the gyrocom- pass having the following characteristics can be directly connected; modification of the GYRO CONVERTER Board is not necessary.

AC synchronous signal: 50/60 Hz

Rotor voltage: 60 V to 135 V AC

Stator voltage: 60 V to 135 V AC

Gear ratio: 360x

Supply voltage: 30 V to 135 V AC

If the specifications of the gyrocompass differ from those mentioned above, change jumper wire and DIP switches settings on the GYRO CONVERTER Board. Set- tings may be changed according to gyrocompass specifications or make and model of gyrocompass (see page 4-5). For the location of DIP switches and jumper wires, see page 4-6.

4-3

Image 42
Contents Marine Radar B . N o . I M E 3 4 6 4 0 M Safety Instructions Power Switch in AC Powered Display Unit Power SwitchTable of Contents Equipment Lists Standard SupplyOptional Equipment Name Type Code No Qty RemarksSystem Configuration Scanner Unit Mounting considerationsBe sure to remove the guide pins Assembling the scanner unitFastening the scanner unit to the mounting platform Fastening the radiator to the radiator bracketScanner unit, front view Before mounting the display unit Mounting procedureDisplay Unit Tabletop mountingStay Setting catch to hole in stay 11 How to dismount the PTU cover Console type mountingDisplay unit modification procedure Separating the control headSeparate type control head kit Type OP03-151, No Control head modification procedure 13 Detaching the control headPlate Connection of display unit to control head15 How to attach KB fixing plate Attachment of hoodWiring Scanner unit, front view, cover removed Correct seating of waterproofing gasket Fabricating signal cable S03-75 Fabricating signal cable S03-74 =EMI cores Outer cores RFC-13 thick Inner cores RFC-10 thinFabricating the AC power cable supplied DPYCY-3.5Fabricating the DC power cable CVV-S 8 x 2C, option CVV-S 82CCable fed from rear of display unit Default Leading in cables to the display unitCable fed from outside display unit Cables fed from bottom of display unit for console mountConnections M4X8 2 pcsConnectors on the INT Board Connectors on the INT BoardChanging AC Power Specification How to attach NH connectorAdjusting Video Signal Level Tuning InitializationAccessing Menus for Initialization and Adjustment Restoring default settingsHeading Alignment Picture appears Deviated counterclockwiseAdjusting Sweep Timing Suppressing Main BangConfirming Magnetron Heater Voltage Magnetron heater voltage ratingInitial Setting Menus Press Radar Menu 0 0 0Initial SETTING1 menu Initial SETTING2 menuInitial SETTING3 menu Initial SETTING4 menu OWN Ship Information menuInstallation and connection of the Gyro Converter Board Gyro Converter GC-8Gyro Converter Board 64P1106 Connection of external power supply DIP switch, jumper wire settingsDefault setting Setting method 1 by gyrocompass specifications Gyrocompass type FrequencySetting method 2 by make and model of gyrocompass JP1 JP2 JP3 JP4 JP5Setting the heading readout on the radar display SW1Installation of the ARP board ARP Board ARP-26ARP board adjustment ARP Board 18P9002BFinal check ARP Board ARP-26RP Board RP-26 Table top/console type10 Display pedestal Separate type control head Necessary parts RP-26-Z-2E Code no13 Display pedestal, front view Performance Monitor PM-30 Necessary parts PM-30 and OP03-150 Code noAlarm Kit ProcedureNecessary parts OP03-156 Code no 16 Display unit, inside view AC-DC Conversion Kit Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page